Login

User Name  
Password  
Create account

Who is online

We have 43 guests and no members online

Wall Hung Boilers Traditional

  • Taura D "the bithermal, ultra-slim"
    • Open-vented boilers (mod. MCA) and room-sealed boilers (mod. MCS) designed for heating and domestic hot water production, high efficiency.
    • Ultra compact size.
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Innovative combustion control, which guarantees hygienic combustion under various operating conditions (mod. MCS).
    • COMFORT operation: thanks to the special constant heat exchanger temperature system, domestic hot water is dispensed even more quickly and comfortably.
    • ECO operation: domestic hot water production occurs according to traditional standards.
    • Designed for possible operation with low temperature systems.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • High-efficiency bithermal copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. MCS).
    • Electronically controlled proportional modulation, on both the DHW and the heating circuits.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. MCA).
    • Self-diagnosis check with display and fault history on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 7-litre expansion vessel (mod. 24) and 10-litre capacity (mod. 32).
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flow switch.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • Frost protection heating elements for protection up to -15°C.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of Taura (mod. MCA).
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG open-vented boilers.

    Certification

    • Taura D boilers are certified EC.

     

    Panel adjustment and control:

     

    pannello di controllo

     

    1. Keys increase / decrease parameters and setting DHW temperature.

    2. Keys increase / decrease heating system temperature setting.

    3. Displays.

    4. Reset Button, Select Summer / Winter mode, Menu "Sliding temperature".

    5. Selection key Economy / Comfort mode, On / Off device.

    6. Hydrometer.

     

    The solar function:

     

    funzione solare

     

    1. Taura D.

    2. Panels.

    3. Plant.

    4. Thermo-sanitary Utilities.

    5. Thermostatic mixing valve.

    6. Entry cold water.

     

    Technical data:

     

    Taura D

    U.M. 24 MCA W Top 24 MCS W Top 32 MCA W Top 32 MCS W Top
    Useful power (min - max) kW 7 - 23,5 7,2 - 24 9,7 - 31,3 9,9 - 32
    Power hearth kW 8,3 - 25,8 8,3 - 25,8 11,5 - 34,4 11,5 - 34,4
    Yield useful to 100% % 91 93 91 93,1
    Yield useful 30% of the flow % 89,6 90,5 89,8 91
    Energy efficiency marking (CE 92/42)   ** *** ** ***
    NOx class   3 3 3 3
    Pressione circuito riscaldamento (max) bar 3 3 3 3
    Expansion tank heating circuit l 7 7 10 10
    Adjusting heating temperature °C 30/85 30/85 30/85 30/85
    Temperature adjustment D.H.W. (max) °C 40/50 40/50 40/50 40/50
    Production D.H.W. ΔT 30°C (max - min) l/min. 11,2 - 2,5 11,4 - 2,5 14,9 - 2,5 15,2 - 2,5
    Pressure hot water circuit (min - max) bar 0,25 - 9 0,25 - 9 0,25 - 9 0,25 - 9
    Heating flow Ø 3/4” 3/4” 3/4” 3/4”
    Heating return Ø 3/4” 3/4” 3/4” 3/4”
    Cold water inlet Ø 1/2” 1/2” 1/2” 1/2”
    Hot water outlet Ø 1/2” 1/2” 1/2” 1/2”
    Gas connection Ø 1/2” 1/2” 1/2” 1/2”
    Total power consumption W 80 110 90 135
    Weight kg 25 30 30 35
  • iXstorage
    • Open-vented boilers (mod. A) and room-sealed boilers (mod. S) for heating and domestic hot water production, high efficiency, even at minimum power.
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for operation with low temperature systems.
    • Designed for control and adjustment via remote control.
    • Functions: frost protection, post-circulation and air purge.
    • High-efficiency monothermal primary copper heat exchanger.
    • Stainless steel 50-litre storage cylinder covered with high density polystyrene.
    • Stainless steel aspirated burner for all gas types.
    • Combustion chamber insulated with ceramic fibre.
    • Room-sealed combustion circuit with electric flue electric flue gas exhaust fan, self-regulating via pressure transducer (mod S).
    • Microprocessor-controlled printed circuit board designed for possible external sensor.
    • Electronically controlled proportional modulation, on both the DHW and the heating circuits.
    • Digital control panel with multi-function backlit graphic display for easy parameter set-up.
    • Electronic ignition with ionisation flame control.
    • Slow opening gas valve.
    • Circulation pump on heating circuit.
    • 8-litre expansion vessel.
    • 2-litre DHW expansion vessel.
    • Electric three-way valve.
    • Automatic by-pass.
    • IP X5D protection rating.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • External sensor and box zone Mix.
    • Frost protection heating elements for protection up to -15°C.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG boilers

    Certification

    • iXstorage boilers are certified EC.

     

    Control Panel:

     

    Pannello comandi

     

    1. Heating temperature setting.

    2. DHW temperature adjustment.

    3. Display mode of operation, diagnostics, boiler parameters.

    4. Selector Summer / Winter mode.

    5. Selector Economy / Comfort mode.

    6. Reset button.

    7. Key menu "sliding temperature".

    8. Ignition key on and off.

     

     

    Technical data:

    Modello U.M. iXstorage 24A iXstorage 24S iXstorage 28A iXstorage 28S
    Thermal power to the fireplace kW 25,8 25,8 30 30
    Useful thermal output (min - max) kW 7,0 - 23,5 7,2 - 24,0 8,5 - 27,3 8,7 - 27,9
    Thermal efficiency (100%) % 91 93,1 91 93,1
    Thermal efficiency (30%) % 89,6 90,5 89,8 91
    Energy efficiency (CEE 92/49) - ** *** ** ***
    NOx class - 3 3 3 3
    Adjustable temperature heating °C 20 - 90 20 - 90 20 - 90 20 - 90
    DHW temperature adjustment °C 30 - 65 30 - 65 30 - 65 30 - 65
    Max operating pressure boiler / health bar 3,0 / 8,0 3,0 / 8,0 3,0 / 8,0 3,0 / 8,0
    Capacity D.H.W. (Δt 30 °C) litri/min 11,2 11,5 13 13
    Water content in the boiler litri 9 9 9 9
    Water content in the micro storage litri 50 50 50 50
    Expansion tank boiler litri 8 8 8 8
    Electrical power consumption (230V - 50Hz) W 80 110 90 135
    Noisiness dB(A) 45 46,5 45 46,5
    Empty weight kg 72 44 67 67

     

    Management facility kettle, low temperature and solar:

     

    Impianto

     

    1. IXstorage.

    2. Plant at high temperature.

    3. External probe.

    4. Zone valves.

    5. DHW pump.

    6. Supplies care.

    7. Entry cold water.

    8. Thermostat area.

    9. Timer Remote CRM.

     

    Dimensions (mm):

     

    Dimensioni

     

    Model A (mm) B (mm) C (mm)
    iXstrorage 24 A 130 176 220
    iXstrorage 24 S * 209,5 213
    iXstrorage 28 A 140 176 220
    iXstrorage 28 S * 209,5 213

     

     

    Installation template (mm):

     

    Dima


    C (Hot water): Ø 1/2''.

    F (Boiler feed water): Ø 1/2''.

    G (Gas): Ø 1/2'' diameter * 3/4'' **.

    M (CH flow): Ø 3/4''.

    R (System return): Ø 3/4''.

    RC (Recirculation): Ø 1/2''.

    AE (Power Supply): Ø 18 mm.

    GS (Hooks support): Ø 10 mm.

    VS (Safety valve): Ø 20 mm.

    N.B. Provide couplings. * (developed) ** (in the boiler).

     

    Features circulator:

     

    Caratteristiche circolatore

    1,2,3: Speed ​​circulatory.  A: Loss of load boiler

     

  • IXtech D
    • Wall-hung open-vented boilers (mod.MC) and room-sealed boilers (mod. MCS), high efficiency, for heating and instant domestic hot water production with 5-litre micro storage tank.
    • Solar function
    • The LPG version is supplied with a nozzle kit.

     

    Control Panel:

     

    Pannello comandi

    1. Heating temperature setting.

    2. DHW temperature adjustment.

    3. Display mode of operation, diagnostics, boiler parameters.

    4. Selector Summer / Winter mode.

    5. Selector Economy / Comfort mode.

    6. Reset button.

    7. Key menu "sliding temperature".

    8. Ignition key on and off.

     

    Technical data:

     

    Model U.M. iXtech D 24MC iXtech D 24MCS iXtech D 28MCS
    Thermal power to the fireplace kW 25,8 25,8 30
    Useful thermal output (min - max) kW 7,0 - 23,5 7,2 - 24,0 8,7 - 27,9
    Thermal efficiency (100%) % 91 93 93,1
    Thermal efficiency (30%) % 89,6 90,5 91
    Energy efficiency (CEE 92/49) - ** *** ***
    NOx class - 3 3 3
    Adjustable temperature heating °C 20 - 90 20 - 90 20 - 90
    DHW temperature adjustment °C 30 - 65 30 - 65 30 - 65
    Max operating pressure boiler / health bar 3,0 / 9,0 3,0 / 9,0 3,0 / 9,0
    Flow D.H.W. (Δt 30 °C) litri/min 11,2 11,5 13,3
    Water content in the boiler litri 0,8 / 0,35 0,8 / 0,35 1,2 / 0,45
    Water content in the micro storage litri 5 5 5
    Expansion tank boiler litri 10 10 10
    Electrical power consumption (230V - 50Hz) W 80 110 135
    Noisiness dB(A) 45 46,5 46,5
    Empty weight kg 38 41 72

     

     

    Management facility kettle, low temperature and solar:

     

    Impianto

    1. Heating.

    2. IXtech D.

    3. Kettle BDS N.

    4. The solar panels.

    5. Thermostatic mixing valve.

    6. Hydraulic kit solar.

    7. Supplies care.

    8. Entry cold water.

    9. External probe.

    10. Timer Remote CRM.

     

    Dimensions (mm):

     

    Dimensioni

     

    Model A (mm) B (mm) C (mm)
    iXtech D 24MC 131 209 236
    iXtech D 24MCS * 225 224
    iXtech D 28MCS * 225 224

    * Fittings fireplace: concentric exhaust or dual exhaust.

     

    Installation template (mm):

     

    Dima

     

    C (hot water): Ø 1/2''.

    F (boiler feed water): Ø 1/2''.

    G (Gas): Ø 1/2'' diameter * 3/4'' **.

    M (CH flow): Ø 3/4''.

    R (system return): Ø 3/4''.

    AE (Power Supply): Ø 18 mm.

    GS (Hooks support): Ø 10 mm.

    VS (safety valve): Ø 23 mm.

    N.B. Provide couplings. * (developed) ** (in the boiler).

     


    Features circulator:

     

    Caratteristiche circolatore

    1,2,3: Speed ​​circulatory;  A: Loss of load boiler.

  • FL
    • Wall-hung open-vented boilers (mod. A) and room-sealed boilers (mod. S), high efficiency, designed for heating and domestic hot water production with plate heat exchanger.
    • Solar function.
    • The open-vented LPG combined versions are supplied with a nozzle kit.
    • Innovative control flame ionization which guarantees hygiene of combustion to the various operating conditions by adjusting electronically the supply of gas without the need for use of the common air pressure switch (mod. MCS).
    • Proportional modulation electronically managed on the domestic circuit and the heating circuit.
    • Predisposition to operate with low temperature systems.
    • Operation comfort: thanks to the particular system operating temperature of the heat exchanger, the hot water is becomes even more rapid and comfortable.
    • Mono-copper heat exchanger with high efficiency.
    • Combustion chamber insulated with ceramic fiber.
    • High head pump with anti-lock system.
    • Taken to the gas sampling series in the boiler (mod. MCS).
    • Safety FLUE CONTROL lifesaving device against the return of the combustion gases in the environment (mod. MCA).

     

    Panel adjustment and control:

     

    Pannello

     

    1. Keys increase / decrease parameters and setting DHW temperature.

    2. Decrease button / temperature setting increase in the heating system.

    3. Displays.

    4. Reset Button, Select Mode, Summer / Winter Menu "Sliding Temperature".

    5. Selection key Economy / Comfort mode, On / Off device.

    6. Hydrometer.

     

    Technical data:

     

    Model FL 24 MCA FL 24 MCS FL 32 MCA  FL 32 MCS 
    Thermal power to the fireplace 8,3 - 25,8 8,3 - 25,8 11,5 - 34,4 11,5 - 34,4
    Useful thermal output (min - max) 7,0 - 23,5 7,2 - 24,0 9,7 - 31,3 9,9 - 32,0
    Thermal efficiency (100%) 91 93 91 93,1
    Thermal efficiency (30%) 89,6 90,5 89,8 91
    Energy efficiency (Dir. 92/42 EEC) ** *** ** ***
    NOx class 3 3 3 3
    Pressure heating (min - max) 0,8 - 3,0 0,8 - 3,0 0,8 - 3,0 0,8 - 3,0
    Maximum temperature heating 90 90 90 90
    Heating temperature adjustment (min - max) 30 - 85 30 - 85 30 - 85 30 - 85
    Heating water content / health 1,0 - 0,2 1,0 - 0,2 1,2 - 0,3 1,2 - 0,3
    Heating expansion tank (capacity) 8 8 8 8
    Pressure health (min - max) 0,25 - 9,0 0,25 - 9,0 0,25 - 9,0 0,25 - 9,0
    DHW temperature adjustment (min - max) 40 - 55 40 - 55 40 - 55 40 - 55
    Flow D.H.W. (Δt 25°C - 30°C) 11,2 11,4 14,9 15,2
    Electrical power consumption (230 V / 50 Hz) 80 110 90 135
    Highest prevalence fireplace - 90 - 130
    Weight empty 27 32 30 35

     

    Template, bindings and sizes (mm):

     

    Dima

     

    A (system delivery): Ø 3/4''

    B (hot water outlet): Ø 1/2''

    C (Gas): Ø 1/2'' diameter * 3/4'' **

    D (cold water inlet): Ø 1/2''

    E (Return installations): Ø 3/4''

    F (safety valves): Ø 27 mm

    N.B. Provides couplings. * (developed) ** (in the boiler).

  • FL Low NOx
    • Wall-hung open-vented boilers (mod. MCA) and room-sealed boilers (mod. MCS), ultra high efficiency, designed for heating and domestic hot water production with plate heat exchanger.
    • Water cooled burner affording ultra low NOx emissions, made of
      stainless steel.
    • efficiency level: 3 stars both in the room-sealed and open-vented versions.
    • NOx class 5.
    • Solar function.
    • The LPG version is supplied with a nozzle kit.

     

    Panel adjustment and control:

    Pannello

     

    1. Keys increase / decrease parameters and setting DHW temperature.

    2. Decrease button / temperature setting increase in the heating system.

    3. Displays.

    4. Reset Button, Select Mode, Summer / Winter Menu "Sliding Temperature".

    5. Selection key Economy / Comfort mode, On / Off device.

    6. Hydrometer.

     


    Technical data:

     

    Model FL LOW NOX 24 MCA FL LOW NOX 24 MCS
    Thermal power to the fireplace 10,0 - 25,8 10,0 - 25,8
    Useful thermal output (min - max) 9,2 - 24,0 9,2 - 24,0
    Thermal efficiency (100%) 93 93
    Thermal efficiency (30%) 92,8 92,8
    Energy efficiency (Dir. 92/42 EEC) *** ***
    NOx class 5 5
    Pressure heating (min - max) 0,8 - 3,0 0,8 - 3,0
    Maximum temperature heating 90 90
    Heating temperature adjustment (min - max) 30 - 85 30 - 85
    Heating water content / health 1,2 - 0,2 1,2 - 0,2
    Expansion tank heating (capacità) 8 8
    Pressure health (min - max) 0,25 - 9,0 0,25 - 9,0
    DHW temperature adjustment (min - max) 40 - 55 40 - 55
    Flow D.H.W. (Δt 25°C - 30°C) 11,4 13,7 - 11,4
    Electrical power consumption (230 V / 50 Hz) 80 110
    Highest prevalence fireplace - 100
    Weight empty 28 33

     

    Features circulators:

     

    Circolatori

    1-2-3: Circulatory Speed​​: A: Loss of boiler load.

© Copyright Lamborghini Calor 2014. All Rights Reserved.
Lamborghini Calor S.p.A. - Via Statale, 342 - C.P. 46 - 44047 Dosso - FE - Italy - UNI EN ISO 9001 Certified Company
Capitale Sociale € 827.112,00 int. vers. - Cod. Fisc. - P.Iva e Reg. Impr. Ferrara n° 00173420381 Sole Shareholder Management and coordination of Ferroli S.p.A.