View the products of the following categories

  • Discontinued water heaters

  • Discontinued wall-hung atmospheric boilers

  • Discontinued wall-hung condensing boilers

  • Discontinued floor-standing boilers

  • Discontinued floor-standing condensing boilers

  • Discontinued burners

  • Discontinued Hot Air Generators

Other discontinued products

  • Sil
    • Open-vented water heaters (mod. Sil) and room-sealed water heaters (mod. Sil S) designed for the production of domestic hot water.
    • High-efficiency copper heat exchanger.
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. Sil S).
    • Continuous modulation gas valve.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. Sil)
    • Combustion chamber insulated with ceramic fibre (mod. Sil S).
    • Control panel fitted with selector switch, thermostat and failure indicator light.
    • DHW flowmeter.
    • IP X4D protection rating.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Type DPO/B polyphosphate feeder.
    • See the Accessories section for further details.

    Certification

    • Sil water heaters are certified EC.
  • SAL
    • High efficiency water heater with storage tank
  • INOVA E
    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) for heating and hot water production, high efficiency (2 stars)
    • Electronically controlled single-sensor system continuous modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC TOP.
    • High-efficiency copper heat exchanger
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Concealed instruments to control and adjust the unit.
    • Designed to accommodate time programmer.
    • Instant heat exchanger for domestic hot water.
    • Hydraulic 3-way valve
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS TOP.
    • IP X4D protection rating.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy front access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • The INOVA E boiler is certified EC.

    Range

    • INOVA E MC W TOP heating and domestic hot water production, open-vented, high efficiency.
    • INOVA E MCS W TOP heating and domestic hot water production, room-sealed, high efficiency.
  • INOVA L
    • High efficiency open-vented boilers designed for heating and domestic hot water production.
    • Designed for possible operation with low temperature systems.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting.
    • High-efficiency copper heat exchanger
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Concealed instruments to control and adjust the unit.
    • Designed to accommodate time programmer
    • Instant plate heat exchanger for domestic hot water.
    • Hydraulic 3-way valve.
    • By-pass
    • Designed to accommodate remote kit
    • IP X4D protection rating.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy front access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • INOVA L boilers are certified EC.
  • XILO T
    • Open-vented boiler (mod. M) and room-sealed boiler (mod. MS) designed for heating.
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MS.
    • Electronically controlled proportional modulation on the heating circuit
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. M.
    • High-head circulation pump
    • 8-litre expansion vessel
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MS)
    • IP X4D protection grade
    • XILO T 24 boilers are designed to be combined with PAC B water cylinders.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO T boilers are certified EC.
  • XILO 'compact bithermal'
    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and domestic hot water production.
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC
    • High-efficiency bithermal copper heat exchanger.
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod.MCS)
    • Priority flowmeter.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • IP X4D protection rating.
    • Hydraulic connections supplied with the product

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Type DPO/B polyphosphate feeder
    • See the Accessories section for further details.

    Certification

    • XILO boilers are certified EC.
  • XILO D

    XILO D 'compact monothermal'

    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and domestic hot water production
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Instant plate heat exchanger for domestic hot water
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC.
    • By-pass
    • High-head circulation pump
    • 8-litre expansion vessel
    • Electric three-way diverter valve
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS)
    • Priority flowmeter
    • IP X4D protection grade
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO D boilers are certified EC.
  • VELA XN "wall-hung with water cylinder"
    • Open-vented boiler (mod. MB) and room-sealed boiler (mod. MBS) for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • Designed for possible operation with low temperature systems.
    • Electronically controlled continuous modulation on the DHW circuit and heating circuit.
    • 60-litre stainless steel storage cylinder.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MB
    • Anti-Legionella function
    • Copper heat exchanger
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre heating circuit expansion vessel.
    • 2-litre DHW circuit expansion vessel.
    • Instruments to control and adjust the unit.
    • Electric three-way valve.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MBS.
    • By-pass.
    • IP X4D protection grade
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • VELA XN boilers are certified EC.
  • ALMA "wall-hung with water cylinder"
    • Open-vented boilers (mod. MB) and room-sealed boiler (mod. MBS) for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • 50-litre stainless steel storage cylinder.
    • Copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Combustion chamber insulated with ceramic fibre.
    • Electronic ignition with ionisation flame control.
    • Electronically controlled continuous modulation on the DHW circuit and heating circuit.
    • Designed for possible operation with low temperature systems.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MBS.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MB.
    • Slow opening gas valve.
    • 8-litre heating circuit expansion vessel.
    • 2-litre DHW circuit expansion vessel.
    • High-head circulation pump.
    • Electric three-way valve.
    • Control panel.
    • Heating and DHW temperature control.
    • Flue gas inspection points supplied as standard in the boiler (mod.MBS)
    • Fault display.
    • Frost protection function.
    • Post-circulation function.
    • Anti-Legionella function.
    • By-pass.
    • IP X4D protection grade
    • Designed to accommodate digital time programmer (mod. MBS).
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • ALMA boilers are certified EC.
  • NINFA 'compact monothermal'
    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C.
    • Designed for possible operation with low temperature systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC.
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel (mod. 24) 10-litre capacity (mod. 32).
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flowmeter, 3-way valve and by-pass.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.
    • Functions: frost protection, post-circulation, solar, air purge and pre-heat.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Frost protection kit, to protect the DHW circuit, for operation up to -15°C of the boiler.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of NINFA open-vented version boilers.
    • External sensor.
    • See the Accessories section for further details.

    Certification

    • NINFA boilers are certified EC.
  • NINFA T
    • Open-vented boiler (mod. M) and room-sealed boiler (mod. MS) designed for heating, high efficiency (3 stars for the room-sealed versions).
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C.
    • Designed for possible operation with low temperature systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MS.
    • Electronically controlled proportional modulation on the heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. M.
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod. MS).
    • Priority flowmeter and by-pass.
    • Designed to accommodate possible external water cylinder with a 3-way valve.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.
    • Functions: frost protection, post-circulation and air purge.
    • NINFA T boilers are designed to be combined with PAC S water cylinders.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of NINFA T open-vented version boilers.
    • External sensor.
    • See the Accessories section for further details.

    Certification

    • NINFA T boilers are certified EC.
  • NOVA DM
    • Room-sealed boilers designed for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • Stainless steel aspirated burner for all gas types.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water production with 5-litre micro storage tank insulated with polyurethane foam.
    • Electronic ignition with ionisation flame control.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • Room-sealed combustion circuit with electric flue gas exhaust fan.
    • Slow opening gas valve.
    • 8-litre expansion vessel.
    • Electric three-way valve.
    • Adjustable by-pass.
    • Designed for operation with low temperature systems.
    • Designed for control and adjustment via remote control.
    • Designed for operation with external sensor.
    • IP X4D protection rating.
    • Functions: frost protection, post-circulation, solar, air purge and pre-heat.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • NOVA DM boilers are certified EC.
  • Ninfa N "compact monothermal"
    • Open-vented boilers (mod. MCA) and room-sealed boilers (mod. MCS) designed for heating and hot water production, high efficiency.
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for possible operation with low temperature systems.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. MCS).
    • Combustion chamber insulated with ceramic fibre.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. MCA).
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel (mod. 24) 10-litre capacity (mod. 32).
    • Slow opening gas valve.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flowmeter, 3-way valve and by-pass.
    • Functions: air purge, pre-heat and post-circulation.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix and external sensor.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of Ninfa N open-vented version boilers.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG open-vented boilers.

    Certification

    • Ninfa N boilers are certified EC.
  • Ninfa N T
    • Open-vented boilers (mod. TCA) and room-sealed boilers (mod. TCS) designed for heating, high efficiency.
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C.
    • Designed for possible operation with low temperature systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. TCS).
    • Combustion chamber insulated with ceramic fibre.
    • Electronically controlled continuous modulation on the heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. TCA).
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel.
    • Electric three-way valve for possible management of a water cylinder.
    • Water cylinder connectors supplied as standard.
    • Slow opening gas valve.
    • Flue gas inspection points supplied as standard in the boiler (mod. TCS).
    • Priority flowmeter.
    • Automatic by-pass.
    • Functions: air purge and post-circulation.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • External sensor and water cylinder sensor.
    • Box zone Mix.
    • Windproof kit, indispensable for operation outdoors
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG boilers

    Certification

    • Ninfa N T boilers are certified EC.
  • iXtech
    • Open-vented boilers (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and hot water production, high efficiency, even at minimum power.
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for operation with low temperature systems.
    • Designed for control and adjustment via remote control.
    • Functions: frost protection, post-circulation, air purge and pre-heat.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water production with 5-litre micro storage tank, covered with high density polystyrene.
    • Stainless steel aspirated burner for all gas types.
    • Combustion chamber insulated with ceramic fibre.
    • Room-sealed combustion circuit with electric flue gas exhaust fan, self-regulating via pressure transducer (mod.MCS).
    • Microprocessor-controlled printed circuit board designed for possible external sensor.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Electronic ignition with ionisation flame control.
    • Slow opening gas valve.
    • Circulation pump on heating circuit.
    • 8-litre expansion vessel.
    • 0,15-litre DHW expansion vessel.
    • Electric three-way valve.
    • Automatic by-pass.
    • IP X5D protection rating.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • External sensor.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG open-vented boilers.

    Certification

    • iXtech boilers are certified EC.
  • Ninfa N Low NOx "Ultra Low Emissions"
    • Open-vented boilers (mod. MCA) and room-sealed boilers (mod. MCS) designed for heating and hot water production, high efficiency.
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for possible operation with low temperature systems.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • Water cooled burner affording ultra low NOx emissions, made of stainless steel, for all gas types.
    • NOx emission class = 5 (.<70 mg/kWh).
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water.
    • Electronic ignition with ionisation flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. MCS).
    • Combustion chamber insulated with ceramic fibre.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. MCA).
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel.
    • Slow opening gas valve.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flowmeter, 3-way valve and by-pass.
    • Functions: air purge, pre-heat and post-circulation.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix and external sensor.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of Ninfa N open-vented version boilers.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG boilers

    Certification

    • Ninfa N Low NOx boilers are certified EC.
  • Taura
    • Open-vented boilers (mod.MC) and room-sealed boilers (mod. MCS), bithermal, designed for heating and instant hot water production, high efficiency.
    • Solar function (mod. 24).
  • NOVA
    • High efficiency room-sealed boiler, bithermal, designed for heating and instant domestic hot water production.
    • Hydraulic connections supplied as standard.
  • NOVA D
    • High efficiency room-sealed boilers, monothermal, designed for heating and domestic hot water production.
    • Hydraulic connections supplied as standard.
  • XILO N T
    • Room-sealed boiler designed for heating, high efficiency (3 stars)
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MS.
    • Electronically controlled proportional modulation on the heating circuit
    • High-head circulation pump
    • 8-litre expansion vessel
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MS)
    • IP X4D protection grade
    • XILO T 24 boilers are designed to be combined with PAC B water cylinders.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO T boilers are certified EC.
  • XILO N
    • Room-sealed boiler designed for heating and hot water production, high efficiency (3 stars)
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • High-efficiency bithermal copper heat exchanger.
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod.MCS)
    • Priority flowmeter.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • IP X4D protection rating.
    • Hydraulic connections supplied with the product

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Type DPO/B polyphosphate feeder
    • See the Accessories section for further details.

    Certification

    • XILO boilers are certified EC.
  • XILO N D
    • Room-sealed boiler designed for heating and hot water production, high efficiency (3 stars)
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Instant plate heat exchanger for domestic hot water
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit
    • By-pass
    • High-head circulation pump
    • 8-litre expansion vessel
    • Electric three-way diverter valve
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS)
    • Priority flowmeter
    • IP X4D protection grade
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO D boilers are certified EC.
  • INOVA
    • Open-vented boiler (mod. C) and room-sealed boilers (mod. CS) designed for domestic hot water production, high efficiency
  • FUTURIA N 'thermo'
    • Ultra high efficiency room-sealed condensing boilers designed for heating.
    • Aluminium lamella heat exchanger affording ultra high heat exchange.
    • Ceramic total premix burner with reverse micro-flame.
    • Ideal for operation with low temperature systems.
    • Designed hydraulically and electrically to accommodate the water cylinder kit (circulation pump, water cylinder and temperature sensor).
    • Variable opening pneumatic gas valve.
    • Microprocessor-controlled printed circuit board designed for connection with the cascade control unit and possible external sensor.
    • Variable speed fan.
    • Electronically controlled continuous modulation with constant air/gas ratio.
    • Operation with methane or LPG.
    • Electronic ignition with ionisation flame control.
    • Concealed instruments to control and adjust the unit.
    • High-head circulation pump on the circuit for heating.
    • 10-litre expansion vessel (models 15, 25 and 35).
    • Non-return valve.
    • Condensation drain siphon.
    • LPG kit supplied with the boiler.
    • NOx emission class = 5.
    • IP X4D protection rating.

    Installation and maintenance

    • Possibility of managing several easy-assembly cascade-operating modular stations. The electronics fitted on the appliance are already designed for connection to the microprocessor-controlled cascade management and control unit.
    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.
    • When a Ø60/Ø100 concentric kit has to be installed, the kit code 08516310 "Flanged concentric connector kit" must under all circumstances be inserted between the boiler and the concentric kit.

    Certification

    • FUTURIA N boilers are certified EC.
  • FUTURIA N 'instant'
    • Ultra high efficiency room-sealed condensing boiler designed for heating and domestic hot water production.
    • Aluminium lamella heat exchanger affording ultra high heat exchange.
    • Ceramic total premix burner with reverse micro-flame.
    • Ideal for operation with low temperature systems.
    • 5-litre micro DHW storage tank insulated with polystyrene foam.
    • Instant plate heat exchanger for domestic hot water.
    • Variable opening pneumatic gas valve.
    • Microprocessor-controlled printed circuit board designed for connection with the cascade control unit and possible external sensor.
    • Variable speed fan.
    • Electronically controlled continuous modulation on both circuits with constant air/gas ratio.
    • Operation with methane or LPG.
    • Electronic ignition with ionisation flame control.
    • Concealed instruments to control and adjust the unit.
    • Circulation pumps on the DHW circuit and heating circuit.
    • 10-litre heating circuit expansion vessel.
    • Non-return valve.
    • Condensation drain siphon.
    • LPG kit supplied with the boiler.
    • NOx emission class = 5.
    • IP X4D protection rating.

    Installation and maintenance

    • Possibility of managing several easy-assembly cascade-operating modular stations. The electronics fitted on the appliance are already designed for connection to the microprocessor-controlled cascade management and control unit.
    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.
    • When a Ø60/Ø100 concentric kit has to be installed, the kit code 08516310 "Flanged concentric connector kit" must under all circumstances be inserted between the boiler and the concentric kit.

    Certification

    • FUTURIA N boilers are certified EC.
  • iXdyn Condens
    • Ultra high efficiency room-sealed condensing boilers designed for heating and domestic hot water production.
    • Aluminium lamella boiler body with dual function: heat exchanger and condenser.
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Possibility of managing 2 heating temperatures alternately.
    • Ceramic total premix burner with reverse micro-flame.
    • Ideal for operation with low temperature systems.
    • Instant plate heat exchanger for domestic hot water combined with a 25-litre stainless steel dynamic stratification storage tank.
    • Variable opening pneumatic gas valve.
    • Microprocessor-controlled printed circuit board designed for connection with the cascade control unit and possible external sensor.
    • Modulating fan unit with air/gas mixer.
    • Electronically controlled continuous modulation on both circuits with constant air/gas ratio.
    • Operation with methane or LPG.
    • Anti-Legionella function.
    • Electronic ignition with digital flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Circulation pumps on heating and DHW circuits.
    • 8-litre heating circuit expansion vessel.
    • 2-litre DHW circuit expansion vessel.
    • Electric three-way valve.
    • Condensation drain siphon.
    • Automatic by-pass.
    • NOx emission class = 5.
    • IP X5D protection rating.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Remote programmable timer, modulating, with zone management possibility.
    • External sensor.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix.
    • Printed circuit board for zone management.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit.
    • The hydraulic connection kits are supplied with the product.

    Certification

    • The iXdyn Condens boiler is certified EC.
  • FUTURIA N-IN 'ad incasso'
    • Caldaia a condensazione, a camera stagna ad altissimo rendimento adatta per il riscaldamento e la produzione di acqua calda sanitaria.
    • Funzionamento a "tiraggio forzato tipo B23".
    • Scambiatore lamellare in alluminio ad elevatissimo scambio termico.
    • Bruciatore ceramico a premiscelazione totale con microfiamma invertita.
    • Ideale per poter funzionare con impianti a bassa temperatura.
    • Microaccumulo di acqua calda sanitaria, rivestito con polistirolo ad alta densità.
    • Scambiatore istantaneo per acqua calda sanitaria a piastre.
    • Valvola gas di tipo pneumatico ad apertura variabile (temperatura fino a -10°C).
    • Scheda elettronica a microprocessore predisposta al collegamento della centralina di controllo cascata e dell'eventuale sonda esterna.
    • Ventilatore a velocità variabile.
    • Modulazione continua gestita elettronicamente su entrambi i circuiti con rapporto aria/gas costante.
    • Funzionamento a Metano o G.P.L.
    • Accensione elettronica con controllo di fiamma a ionizzazione (temperatura fino a -10°C).
    • Strumentazione per il controllo e la regolazione del gruppo a scomparsa.
    • Circolatori sul circuito sanitario e sul circuito riscaldamento.
    • Vaso di espansione circuito di riscaldamento 8 litri.
    • Valvola di non ritorno.
    • Sifone per scarico condensa.
    • Kit G.P.L. a corredo della caldaia.
    • Classe di NOx = 5.
    • Grado di protezione IP X4D.
    • Comando remoto per il controllo e la regolazione del gruppo.

    Installazione e manutenzione

    • Possibilità di gestire più moduli funzionanti in cascata tra loro. L'elettronica a bordo macchina è già predisposta per l'allacciamento della centralina a microprocessore di controllo e gestione cascata.
    • Installazione caldaia agevole grazie al telaio da incasso ed ai kit allacciamenti idraulici (a richiesta).
    • Semplice manutenzione grazie alla comoda accessibilità ai componenti interni.

    Accessori a richiesta

    • Telaio per incasso della caldaia in lamiera zincata con portellone in 3 sezioni (fumi - combustione - allacciamenti) predisposto per entrata gas e scarico fumi frontali.
    • I kit per l'aspirazione/scarico dei fumi non sono compresi nella fornitura.
    • I kit allacciamenti idraulici non sono compresi nella fornitura.
    • Per ulteriori informazioni vedi Accessori.

    Certificazione

    • Le caldaie FUTURIA N-IN sono omologate CE.

    Come ordinare FUTURIA N-IN?

    • Per ordinare FUTURIA N-IN bisogna ordinare il codice della caldaia (senza mantello) e il codice del telaio.
    • Il kit telaio da incasso può essere ordinato separatamente.
  • MEGA PREX N '1400÷3500'
    • Pressurised boilers, ideal for heating large and medium-sized buildings.
    • Steel boiler body with reverse flame firebox.
    • Operation with light oil and gas burners.
    • External control panel with instruments to control and adjust the unit.
    • Extra-thick insulation against heat dispersion.
    • Hinge-opening door.
    • Stainless steel turbulators.
    • Extra-thick steel flue pipes
    • Well for control thermometers

    Installation and maintenance

    • Boiler plate designed for burner mounting.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • Elettroniko control panel complete with boiler adjustments, flow/return/external sensors, safety devices and designed to accommodate a cascade control unit.
    • See the Accessories section for further details.

    Certification

    • MEGA PREX N boilers are certified EC.

    How to order Mega Prex N?

    • MEGA PREX N boilers are supplied with a standard control panel. If you wish to order the new Elettroniko control panel, please specify at the time of order.This entails a surcharge.
  • Mega "92÷1060"
    • Pressurised boilers, ideal for heating large and medium-sized buildings.
    • Steel boiler body with reverse flame firebox.
    • Operation with light oil and gas burners.
    • External control panel with instruments to control and adjust the unit.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Hinge-opening door with double stop and new-concept lock and centring system.
    • New stainless steel turbulators which improve the heat exchange of flue gases, guaranteeing minimal pressure loss.
    • Extra-thick steel flue pipes.
    • Well for control thermometers.

    Accessories available upon request

    • Elettroniko control panel for operation with 1-stage and 2-stage burners.
    • Elettroniko control panel for operation with 1-stage, 2-stage and modulating burners.
    • See the Accessories section for further details.

    Certification

    • MEGA boilers are certified EC.

    How to order Mega?

    • MEGA boilers are supplied with a standard control panel. If you wish to order the Elektro or Elettroniko control panels, please specify at the time of order.This entails a surcharge. The Elettroniko control panel is only available for versions with "/2" 2-stage burners.
  • Mega "1250÷3600"
    • Pressurised boilers, ideal for heating large and medium-sized buildings.
    • Steel boiler body with reverse flame firebox.
    • Operation with light oil and gas burners.
    • External control panel with instruments to control and adjust the unit.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Hinge-opening door with double stop and new-concept lock and centring system.
    • New stainless steel turbulators which improve the heat exchange of flue gases, guaranteeing minimal pressure loss.
    • Extra-thick steel flue pipes.
    • Well for control thermometers.

    Accessories available upon request

    • See the Accessories section for further details.

    Certification

    • MEGA boilers are certified EC.
  • Mega Star
    • Ultra high efficiency pressurised boilers, ideal for heating large and medium-sized buildings.
    • Steel boiler body with reverse flame firebox.
    • Operation with gas burners.
    • External control panel with instruments to control and adjust the unit.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Hinge-opening door.
    • Stainless steel turbulators.
    • Extra-thick steel flue pipes.
    • Well for control thermometers.

    Accessories available upon request

    • Elettroniko control panel for operation with 1-stage and 2-stage burners.
    • Elettroniko control panel for operation with 1-stage, 2-stage and modulating burners.
    • See the Accessories section for further details.

    Certification

    • MEGA STAR boilers are certified EC.
    • Certified 3 stars up to 400 kW, as well as ultra high efficiency levels.

    How to order Mega Star?

    • MEGA STAR boilers are supplied with a standard control panel. If you wish to order the Elektro or Elettroniko control panels, please specify at the time of order.This entails a surcharge. The Elettroniko control panel is only available for versions with "/2" 2-stage burners.
  • Mega Star 3 "120÷700"
    • Ultra high efficiency pressurised boilers, ideal for heating large and medium-sized buildings.
    • Steel boiler body for 3-stage combustion process with fire-tube firebox.
    • Protective refractory material in the combustion chamber designed to keep the flue gas temperature high.
    • Stainless steel turbulators.
    • Extra-thick steel flue pipes.
    • Hinge-opening door.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Vertically-developing structure with tube bundle positioned above the firebox.
    • Ultra-compact width dimensions (0 cm).
    • External control panel with instruments to control and adjust the unit.
    • Well for control thermometers.
    • Operation with light oil and gas burners.

    Accessories available upon request

    • Elettroniko control panel for operation with 1-stage and 2-stage burners.
    • Elektro control panel for operation with 1-stage, 2-stage and modulating burners.
    • See the Accessories section for further details.

    Certification

    • MEGA STAR 3 boilers are certified EC.
    • Certified 3 stars up to 400 kW, as well as ultra high efficiency levels.

    How to order Mega Star 3?

    • MEGA STAR 3 boilers are supplied with a standard control panel. If you wish to order the Elektro or Elettroniko control panels, please specify at the time of order.This entails a surcharge. The Elettroniko control panel is only available for versions with "/2" 2-stage burners.
  • Mega Star 3 "800÷2300"
    • Ultra high efficiency pressurised boilers, ideal for heating large and medium-sized buildings.
    • Steel boiler body for 3-stage combustion process with fire-tube firebox.
    • Protective refractory material in the combustion chamber designed to keep the flue gas temperature high.
    • Stainless steel turbulators.
    • Extra-thick steel flue pipes.
    • Hinge-opening door.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Vertically-developing structure with tube bundle positioned above the firebox.
    • External control panel with instruments to control and adjust the unit.
    • Well for control thermometers.
    • Operation with light oil and gas burners.

    Accessories available upon request

    • Elettroniko control panel for operation with 1-stage and 2-stage burners.
    • Elektro control panel for operation with 1-stage, 2-stage and modulating burners.
    • See the Accessories section for further details.

    Certification

    • MEGA STAR 3 boilers are certified EC.
    • "Ultra high efficiency" certified boilers.

    How to order Mega Star 3?

    • MEGA STAR 3 boilers are supplied with a standard control panel. If you wish to order the Elektro or Elettroniko control panels, please specify at the time of order.This entails a surcharge. The Elettroniko control panel is only available for versions with "/2" 2-stage burners.
  • Mega Star K
    • They are designed to allow installation in central heating where pre-assembled boilers cannot be introduced. They feature the same technical and mechanical characteristics as boilers from the MEGA STAR range. Individual units are supplied on pallets complete with assembly instructions; once installation is complete, it is vital to carry out a hydraulic test.
    • Operation with gas burners.

    Accessories available upon request

    • Elettroniko control panel for operation with 1-stage and 2-stage burners.
    • Elettroniko control panel for operation with 1-stage, 2-stage and modulating burners.
    • See the Accessories section for further details.

    Certification

    • MEGA STAR K boilers are certified EC.
    • Certified 3 stars up to 400 kW, as well as ultra high efficiency levels.

    How to order Mega Star K?

    • MEGA STAR K boilers are supplied with a standard control panel. If you wish to order the Elektro or Elettroniko control panels, please specify at the time of order.This entails a surcharge. The Elettroniko control panel is only available for versions with "/2" 2-stage burners.

  • Sec
    • Floor-standing boilers designed for heating (mod. Sec and Sec B) and domestic hot water production (mod. Sec B).
    • Cast iron boiler body (mod. Sec B).
    • 90-litre stainless steel cylinder (mod. Sec B) fitted with magnesium anode and connector for recirculation.
    • Circulation pump on DHW circuit.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Operation with light oil and gas burners.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Control and operating instruments.
    • Designed to accommodate time programmer.
    • The Sec boiler can be combined with Pac S and Bitherm water cylinders.

    Accessories available upon request

    • Time programmer kit.
    • See the Accessories section for further details.

    Certifications

    • Sec and Sec B boilers are certified EC.
  • Exa
    • Floor-standing boilers designed for domestic and residential heating.
    • Cast iron boiler body.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Operation with light oil and gas burners.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Control and operating instruments.
    • Exa boilers can be combined with Pac S and Bitherm water cylinders.

    Accessories available upon request

    • Exa-Pac S electrical connection kit
    • See the Accessories section for further details.

    Certification

    • Exa boilers are certified EC
  • Vit
    • Floor-standing boilers designed for heating (mod. Vit R - Vit CI) and domestic hot water production (mod. Vit CI).
    • Cast iron boiler body.
    • Installation facilitated by the pre-assembled burner.
    • Vessel-shaped instant heat exchanger for domestic hot water (mod. Vit CI).
    • Pre-calibrated, pre-assembled light oil burner complete with pre-heater on nozzle.
    • Burner designed to accommodate external air inlet.
    • 10-litre heating circuit expansion vessel.
    • Circulation pump on heating circuit.
    • Electric three-way valve.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Extra-thick insulation against heat dispersion.
    • Control and operating instruments.
    • IP X4D protection rating.

    Electronic control panel, with functions for:

    • Heating temperature control
    • Fault display
    • Frost protection function
    • Post-circulation function

    Certification

    • VIT boilers are certified EC (only for light oil operation).
  • Bia F "room-sealed"
    • Room-sealed floor-standing boilers designed for heating and domestic hot water production.
    • Cast iron boiler body.
    • Installation facilitated by the pre-assembled burner.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Stainless steel water cylinder, covered with high-density polystyrene, 90-litre capacity (Bia F 30-90) and 120-litre capacity (Bia F 40-120), fitted with magnesium anode and connector for recirculation.
    • Burner with external air inlet.
    • 10-litre heating circuit expansion vessel.
    • 4-litre DHW circuit expansion vessel.
    • Circulation pumps on the DHW circuit and heating circuit.
    • Extra-thick insulation against heat dispersion.
    • IP X4D protection rating.

    Pre-assembled and pre-calibrated burner with external air inlet:

    • Gas, with dual valve, stabiliser, filter, air pressure switch and minimum gas pressure gauge.
    • light oil, with conical head, high performance, complete with pre-heater on nozzle.

    Electronic control panel, with functions for:

    • Heating and DHW temperature control.
    • Fault display.
    • Frost protection function.
    • Post-circulation function for differentiated disposal.
    • Anti-Legionella function.

    Certification

    • Bia F boilers are certified EC.

    Gas thermal couplings are available upon request. For delivery lead times, please contact our Sales Dept.

  • Big F
    • Floor-standing boilers designed for heating medium-sized systems.
    • High-quality cast iron boiler body with pre-assembled components.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Operation with light oil and gas burners.
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Control panel with control and operating instruments.
    • IP X0D protection rating.

    Certifications

    • BIG F boilers are certified EC.
  • Axe 3 D
    • Floor-standing boilers designed for domestic and residential heating.
    • Cast iron boiler body for 3-stage combustion process with fire-tube firebox.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Operation with light oil and gas burners.
    • Designed for operation with low temperature systems.
    • Designed for connection to an external domestic hot water cylinder.
    • Boiler plate designed for burner mounting.
    • Boiler body insulation consisting of a thick fibreglass blanket, covered by an aluminium mesh flame-proof film against heat dispersion.
    • Digital control panel with multi-function backlit graphic display for easy parameter set-up.
    • Frost protection function.
    • IP X0D protection rating.

    Accessories available upon request

    • External sensor and water cylinder sensor kit.
    • Remote programmable timer, modulating, with zone management possibility.
    • Zone management control unit kit.
    • See the Accessories section for further details.

    Certification

    • Axe 3 D boilers are certified EC.
  • Axe 3 D B 100
    • Floor-standing boilers designed for heating and domestic hot water production in domestic and residential settings.
    • Cast iron boiler body for 3-stage combustion process with fire-tube firebox.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Vitrified 100-litre storage cylinder covered with high density polystyrene, which can be inspected via handrail.
    • Operation with light oil and gas burners.
    • Designed for operation with low temperature systems.
    • Boiler plate designed for burner mounting.
    • Boiler body insulation consisting of a thick fibreglass blanket, covered by an aluminium mesh flame-proof film against heat dispersion.
    • Digital control panel with multi-function backlit graphic display for easy parameter set-up.
    • 10-litre heating circuit expansion vessel.
    • Circulation pump on DHW circuit.
    • Frost protection function.
    • IP X0D protection rating.

    Accessories available upon request

    • External sensor kit.
    • Remote programmable timer, modulating, with zone management possibility.
    • Zone management control unit kit.
    • See the Accessories section for further details.

    Certification

    • Axe 3 D B 100 boilers are certified EC.
  • Axe 3 D Unit (R-CI)
    • Floor-standing boilers designed for heating (mod. R - CI) and domestic hot water production (mod. CI) for domestic and residential settings.
    • Cast iron boiler body for 3-stage combustion process with fire-tube firebox.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Designed for operation with low temperature systems.
    • Designed for connection to an external domestic hot water cylinder (mod. R).
    • Installation facilitated by the pre-assembled burner.
    • Instant heat exchanger for domestic hot water (mod. CI).
    • Pre-calibrated, pre-assembled light oil burner complete with pre-heater on nozzle.
    • Boiler body insulation consisting of a thick fibreglass blanket, covered by an aluminium mesh flame-proof film against heat dispersion.
    • Digital control panel with multi-function backlit graphic display for easy parameter set-up.
    • 10-litre heating circuit expansion vessel.
    • Circulation pump on heating circuit.
    • Electric three-way valve.
    • Frost protection function.
    • IP X0D protection rating.

    Accessories available upon request

    • External sensor kit (mod. R - CI) and water cylinder sensor (mod. R).
    • Remote programmable timer, modulating, with zone management possibility.
    • Zone management control unit kit.
    • See the Accessories section for further details.

    Certification

    • Axe 3 D Unit (R-CI) boilers are certified EC.
  • Axe 3 D Unit B 100
    • Floor-standing boilers designed for heating and domestic hot water production in domestic and residential settings.
    • Cast iron boiler body for 3-stage combustion process with fire-tube firebox.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Designed for operation with low temperature systems.
    • Installation facilitated by the pre-assembled burner.
    • Vitrified 100-litre storage cylinder covered with high density polystyrene, which can be inspected via handrail.
    • Pre-calibrated, pre-assembled light oil burner complete with pre-heater on nozzle.
    • Boiler body insulation consisting of a thick fibreglass blanket, covered by an aluminium mesh flame-proof film against heat dispersion.
    • Digital control panel with multi-function backlit graphic display for easy parameter set-up.
    • 10-litre heating circuit expansion vessel.
    • 4-litre DHW circuit expansion vessel.
    • Circulation pump on heating and DHW circuits.
    • Frost protection function.
    • IP X0D protection rating.

    Accessories available upon request

    • External sensor kit.
    • Remote programmable timer, modulating, with zone management possibility.
    • Zone management control unit kit.
    • See the Accessories section for further details.

    Certification

    • Axe 3 D Unit B 100 boilers are certified EC.
  • ERA F 90 3 STELLE
    • High efficiency open-vented floor-standing boiler (mod. B) and room-sealed boiler (mod. BS) designed for heating and domestic hot water production.
    • Stainless steel 90-litre storage cylinder.
    • Cast iron body with cross-developing elements.
  • ERA F S 2 STELLE "cast iron floor-standing room-sealed"
    • High efficiency (2 stars) room-sealed boilers designed for heating only.
    • Cast iron body with cross-developing elements.
    • Stainless steel aspirated burner for all gas types.
    • Electronic intermittent pilot ignition with ionisation flame control.
    • Instruments to control and adjust the unit.
    • Room-sealed combustion circuit with electric flue gas exhaust fan.
    • Slow opening gas valve.
    • High-head circulation pump (mod. PK).
    • 10-litre expansion vessel (mod. PK).
    • Safety valve (mod. PK).
    • Automatic air relief valve (mod. PK).
    • Water inlet valve (mod. PK).
    • Boiler drain valve.
    • ERA F S boilers can be combined with water cylinders from the PAC B range.

    Maintenance

    • Easy maintenance thanks to the easy access to internal components (front flap)

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • ERA F S boilers are certified EC
  • ERA F 2 STELLE "Cast iron floor-standing"
    • High efficiency open-vented boilers for heating only.
    • Cast iron body with cross-developing elements
    • Stainless steel aspirated burner for all gas types
  • ERA F 60 2 STELLE "Cast iron, with water cylinder"
    • High efficiency open-vented boilers (mod.B) and room-sealed boilers (mod. BS) designed for heating and domestic hot water production.
    • Stainless steel water cylinder, covered with high-density polystyrene, 55-litre capacity.
  • ERA F 90 2 STELLE "Cast iron, with water cylinder"
    • High efficiency open-vented boilers (mod.B) and room-sealed boilers (mod.BS) designed for heating and domestic hot water production.
    • Stainless steel water cylinder, covered with high-density polystyrene, 90-litre capacity.
  • MEGA PREX
    • Pressurised boilers, ideal for heating large and medium-sized buildings
    • Steel boiler body with reverse flame firebox
    • Operation with light oil and gas burners
  • SILVER S - SILVER BS
    • Ultra high efficiency stainless steel condensing boiler, room-sealed, for heating (mod. SILVER S) and for heating and domestic hot water production (SILVER BS).
    • Ideal for operation with low temperature systems.
    • Boiler body in stainless steel: AISI 316 Ti.
    • Wet base cylindrical firebox with reverse flame.
    • Flue ducts comprising plates pressed on the inside and with a special corrugated shape to increase turbulence and facilitate the formation of condensation.
    • Environmentally-friendly with low NOx emissions.
    • Operation with gas blower burners.
    • 120-litre enamelled steel cylinder covered with polyurethane (SILVER BS).
    • Extra-thick insulation against heat dispersion.
    • Instruments to control and adjust the unit.
    • 14-litre heating circuit expansion vessel
    • 3-litre DHW circuit expansion vessel (SILVER BS).
    • Circulation pumps on the DHW circuit (SILVER BS) and on the heating circuit.
    • IP 40 protection rating.

    Maintenance

    • Easy maintenance thanks to the easy access to internal components.

    Certification

    • SILVER boilers are certified EC.
  • FUTURIA L 'Water cylinder'
    • Ultra high efficiency room-sealed condensing boilers designed for domestic hot water production.
    • Ideal for operation with low temperature systems.
    • Special corrosion-proof cast aluminium single-block heat exchanger.
    • Stainless steel 50-litre storage cylinder insulated with polyurethane foam.
    • Wet type combustion chamber.
    • Stainless steel premix burner.
    • Electronic ignition with ionisation flame control.
    • Electronically controlled continuous modulation on both circuits with constant air/gas ratio.
    • Operation with methane or LPG.
    • Concealed instruments to control and adjust the unit.
    • High-head circulation pump.
    • 8-litre heating circuit expansion vessel.
    • 2-litre DHW circuit expansion vessel.
    • Electric three-way valve.
    • Room-sealed combustion circuit with electric flue gas exhaust fan.
    • NOx emission class = 5.
    • IP X4D protection rating.
    • Condensation drain siphon.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • FUTURIA L boilers are certified EC.
  • REPLY N
    • Ultra high efficiency condensing heating modular station.
    • Single firebox (REPLY N 50) or dual firebox (REPLY N 70 and REPLY N 100) with aluminium lamella heat exchangers affording ultra high heat exchange.
    • Ceramic premix burners with reverse micro-flame.
    • Ideal for operation with low temperature systems.
    • Ideal for outdoor installation, even in entirely exposed settings.
    • Variable opening pneumatic gas valves.
    • Microprocessor-controlled printed circuit board designed for connection with the cascade control unit and possible external sensor.
    • Variable speed fans.
    • Electronically controlled continuous modulation with constant air/gas ratio.
    • Operation with methane or LPG.
    • User interface display for every modular station already installed on the appliance.
    • Electronic ignition with ionisation flame control.
    • Instruments to control and adjust the unit.
    • Independent heat exchanger hydraulic circuits connected to the respective flow and return manifolds.
    • Circulation pumps on primary circuit.
    • Non-return valve.
    • Condensation drain on disposal circuit including siphon.
    • Satin finish AISI 316 stainless steel containment modular station structure, compact size.
    • LPG kit supplied with the boiler.
    • NOx emission class = 5
    • IP X5D protection rating.

    Installation and maintenance

    • Possibility of managing several easy-assembly cascade-operating modular stations. The electronics fitted on the appliance are already designed for connection to the microprocessor-controlled cascade management and control unit.
    • System water flow and return manifolds and gas supply on board the appliance, already flanged for easy installation, complete with blind and connection flanges.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • See the Accessories section for further details.

    Certification

    • REPLY N heating modular stations are certified EC.
  • Reply I
    • Ultra high efficiency condensing heating modular station designed to operate individually or in cascade (max. 5 heating modular stations or 10 fireboxes).
    • Single firebox (Reply 51) or dual firebox (Reply 71 and Reply 101) with aluminium lamella heat exchangers affording ultra high heat exchange.
    • Ceramic total premix burner with reverse micro-flame.
    • Ideal for operation with low temperature systems.
    • Ideal for outdoor installation, even in entirely exposed settings.
    • Variable opening pneumatic gas valves.
    • Microprocessor-controlled printed circuit board designed for Master-Slave cascade connection without the use of further regulators.
    • Modulating fan unit with air/gas mixer.
    • Electronically controlled continuous modulation with constant air/gas ratio.
    • Operation with methane or LPG.
    • Digital controls with large display monitor and optimum temperature management with dual sensor on the flow and return circuit.
    • Electronic ignition with ionisation flame control.
    • Instruments to control and adjust the unit.
    • Independent heat exchanger hydraulic circuits connected to the respective insulated flow and return manifolds.
    • System water flow and return manifolds and gas supply on board the appliance, already flanged for easy installation, complete with blind and connection flanges.
    • Can be combined with the external sensor (on request) for operation with variable temperature and with the remote modulating programmable timer (on request).
    • Circulation pump on heating circuit.
    • Condensation drain on disposal circuit including siphon.
    • Insulated containment modular station structure, in painted galvanised sheet metal (in the basic models) and in satin finish AISI 316 stainless steel (in models I), compact size.
    • NOx emission class = 5
    • IP X5D protection rating.

    Accessories available upon request

    • Hydraulic circuit breaker with modular structure.

    Accessories supplied

    • Methane to LPG conversion kit.

    Certification

    • Reply heating modular stations are certified EC.
  • Eco LN "Domestic Line"
    • Single-stage burners.
    • Certified EN 267 - RAL UZ9 "Blue Angel" (only Eco 2.5 LN).
    • Ultra low emissions.
    • Suitable for medium pressurisation boilers.
    • Combustion head and air control.
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Pre-heater at nozzle.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.

    Installation and maintenance

    • Easy installation and maintenance thanks to the universal perforation mobile flange.

    Accessories supplied

    • 2 flexible hoses, nozzle, nozzle spanner and boiler insulating seal.

    Certification

    • Eco LN burners are certified EC.
  • Pnz "Industrial Line"
    • 2-stage heavy oil burners.
    • Operation with desulphurised heavy oil for low harmful emissions.
    • Suitable for pressurised boilers.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Fitted with flanged heating element with precision thermostat for tank pre-heating.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.

    Installation

    • Easy installation thanks to the sliding flange.

    Accessories supplied

    • 2 flexible hoses.
    • 2 nozzles and nozzle spanner.
    • Boiler insulating seal.

    Accessories available upon request

    • Line filter.

    Certification

    • Pnz burners are certified EC.
  • Pm/2-E "Industrial Line"
    • Two-stage burners.
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. 55 Pm/2-E and 70 Pm/2-E - a conversion kit is necessary).
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Standard valve seal control in models 210, 310 and 430.
    • Shock-resistant electrical panel.
    • Can be combined with various types of ramps for ultimate versatility.
    • Supplied in two boxes (Burner+Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge.
    • Easy installation thanks to the universal perforation sliding flange.

    Accessories available upon request

    • Accessory set kit.
    • Valve seal control kit.
    • See the Accessories section for further details.

    Certification

    • Pm/2-E burners are certified EC.
  • Twin-E - Twin/2-E
    • Single-stage burner (Twin 13-E).
    • Two-stage burners (Twin 50/2-E - Twin 70/2-E - Twin 120/2-E - Twin 180/2-E).
    • Operation with 2 different fuel types, light oil and gas, alternately.
    • Suitable for pressurised boilers.
    • Gas ramp with stabiliser.
    • Valve seal control kit (mod. Twin 120/2-E - Twin 180/2-E).
    • Low emissions.
    • Electrical servo-control on the air shutter (mod. with 2 stages).
    • Combustion head control.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet (mod. Twin 13-E - Twin 50/2-E - Twin 70/2-E).
    • Compact size (mod.Twin 13-E - Twin 50/2-E - Twin 70/2-E).
    • Supplied in 2 boxes (burner + gas ramp).

    Installation and maintenance

    • Easy installation thanks to the universal perforation sliding flange (mod. Twin 13-E - Twin 50/2-E - Twin 70/2-E).
    • Easy access to components.

    Accessories supplied

    • Flexible hoses.
    • Nozzles.
    • Boiler coupling insulating seal.

    Certification

    • Twin-E and Twin 2-E burners are certified EC.
  • Air A
    • Wall-hung room-sealed gas generators.
    • Designed to heat zones.
    • Heat exchanger, combustion chamber and flue gas manifold in a single stainless steel block.
    • Stainless steel atmospheric burner for all gases.
    • Electric flue gas exhaust fan.
    • Electronic ignition.
    • Ionisation flame control.
    • Helical fan unit.
    • Manually adjustable fins.

    Installation and maintenance

    • Easy to install, taking up little space since they are usually installed at least 2.5 m in height.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories supplied

    • LPG nozzles.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • Air A generators are certified EC.
  • Air AC
    • Wall-hung room-sealed ducted gas generators.
    • Designed to heat zones.
    • Heat exchanger, combustion chamber and flue gas manifold in a single stainless steel block.
    • Stainless steel atmospheric burner for all gases.
    • Electric flue gas exhaust fan.
    • Electronic ignition.
    • Ionisation flame control.
    • Centrifugal fan unit

    Installation and maintenance

    • Easy to install, taking up little space since they are usually installed at least 2.5 m in height.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories supplied

    • LPG nozzles.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • Air AC generators are certified EC.

    On request: For delivery lead times, please contact our Sales Dept.

  • Air ACE
    • Wall-hung room-sealed outdoor ducted gas generators.
    • Designed to heat zones.
    • Heat exchanger, combustion chamber and flue gas manifold in a single stainless steel block.
    • Stainless steel atmospheric burner for all gases.
    • Casing treated for outdoor installation.
    • Electric flue gas exhaust fan.
    • Electronic ignition.
    • Ionisation flame control.
    • Centrifugal fan unit.
    • IP X4D protection rating.

    Accessories supplied

    • LPG nozzles.
    • Connector for flow duct.
    • Horizontal connector for air intake.
    • Tilted air intake connector complete with grille.
    • Flue gas exhaust kit.
    • Combustion air intake kit.
    • Remote control panel supplied with electrical cable and sheath - length of 10 m.

    Accessories available upon request

    • See the Accessories section for further details.

    Certification

    • AIR-ACE generators are certified EC.

    On request: For delivery lead times, please contact our Sales Dept.

  • Idro X
    • Ideal in plant engineering solutions where regulations do not permit the installation of appliances directly inside the rooms to be heated.
    • Exonerated from prior approval from the Fire Brigade.

    Boiler

    • High efficiency room-sealed boiler for type (B22) fan flue operation.
    • Electronically controlled proportional modulation.
    • Electronic ignition with ionisation flame control (temperature up to -15°C).
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve (temperature up to -15°C).
    • IP X5D protection rating.
    • Complies with the requirements of Italian Leg.Decrees 192/05 and 311/06;

    Unit heater

    • External casing housing the circulation pump and the expansion vessel, guaranteeing easy access to both.
    • Helical fans (2) fitted with protection grilles and dual speed motor to accommodate the requirements of plant engineering applications requiring low noise levels.
    • Flow grille made with extruded aerodynamically profiled aluminium fins which can be adjusted with respect to their axis.
    • Remote control supplied as standard.
    • Innovative supporting shelf allowing the direction of the unit heater along both the vertical and horizontal axes.

    Installation and maintenance

    • Installation is easy thanks to the template connectors, the boiler piping kits (on request) and the unit heater supporting shelf.
    • Easy maintenance thanks to the easy access to internal components.

    Certification

    • IDRO X generators are certified EC.

© Copyright Lamborghini Calor 2014. All Rights Reserved.
Lamborghini Calor S.p.A. - Via Statale, 342 - C.P. 46 - 44047 Dosso - FE - Italy - UNI EN ISO 9001 Certified Company
Capitale Sociale € 827.112,00 int. vers. - Cod. Fisc. - P.Iva e Reg. Impr. Ferrara n° 00173420381 Sole Shareholder Management and coordination of Ferroli S.p.A.