Login

User Name  
Password  
Create account

Who is online

We have 77 guests and no members online

Gas burners

  • Fime "Standard Line"
    • Single-stage burner.
    • Suitable for medium pressurisation boilers.
    • For methane gas or LPG operation.
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • Combustion head and air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.

    Installation and maintenance

    • Easy installation thanks to the universal perforation mobile flange.
    • Suitable for operation with ramp pressure of 20 mbar and 30 mbar.

    Accessories available upon request

    • Air intake for room-sealed combustion.
    • See the Accessories section for further details.

    Certification

    • Fime burners are certified EC.

     

    Characteristics circulator:

     

    Curva fime

     

    Model Flow (m3/h) Power (kW) Motor
    (230V ~ 50Hz)
    Network attack (Ø) Gauge valve (Ø) Min.Pres.Nat.Gas (mbar*) Min.Pres.GPL(mbar*) Max. Pres. (mbar**)
    FIME 5 S-E 2,3÷3,82 22,86÷38 100 W mon. 1/2” 1/2” 17 13 65

     

    *: Minimum pressure of the gas to get the maximum power of the burner.

    **: Maximum operating pressure of the gas valves.

     

     

    Dimensions (mm):

     

    dimensioni

     

     

     

    Accessory: kit outside air intake port

     

    immagine accessorio

     

    1. Steel hose with a maximum length of 3 meters;

    2. Metal clamps to seal the flexible;

    3. Rigid tube with a diameter of 60 mm for the crossing of the wall;

    4. Windproof terminal located outside the dwelling;

    5. 90° elbow and gasket;

    6. Cover the air intake.

     

     

    Mounting flange and Weight:

     

    flangia

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (mm) M (mm) N (mm) Weight (kg)
    FIME 5 S-E 95 140 40÷180 M8 180 155 12
  • Em-E "Domestic Line"
    • Single-stage burners (Em) and single-stage burners with long nozzle distributor (Em L).
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. Em 16-E - Em 26-E a conversion kit is necessary).
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • Combustion head control (external in mod. Em 26-E - Em 35-E).
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap (excluding mod. Em 35-E).
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge (mod. Em 26-E - Em 35-E).
    • Easy installation thanks to the universal perforation mobile flange (sliding from mod. Em 9-E to Em 35-E).

    Accessories available upon request

    • Accessory set kit.
    • Methane to LPG conversion kit (for mod. Em 16-E and Em 26-E).
    • Valve seal control kit.

    Certification

    • Em-E burners are certified EC.

     

    Characteristics circulator:

     

    Curva em-e

     

    Curva em-e 2

     

    Model Flow (m3/h) Power (kW)    Motor       (230V~50Hz) Network attack (Ø) Gauge valve (Ø) Min. Pres. Nat. gas (mbar**) Min. Pres. G.P.L. (mbar) Max. Pres (mbar)
    EM 3-E.D1 1,19÷3,79 11,9÷37,7 100 W mon. 1/2” 1/2” 12,5 10,5 65
    EM 3-E.D2 1,19÷3,79 11,9÷37,7 100 W mon. 1/2” 1/2” 12,5 - 200
    EM 3-E.D3 1,19÷3,79 11,9÷37,7 100 W mon. 3/4” 1/2” 11 - 360
    EM 6-E.D1 2,71÷6,69 27÷66,6 100 W mon. 1/2” 1/2” 24 14 65
    EM 6-E.D2 2,71÷6,69 27÷66,6 100 W mon. 1/2” 1/2” 24 - 200
    EM 6-E.D3 2,71÷6,69 27÷66,6 100 W mon. 3/4” 1/2” 16 - 360
    EM 9-E.D2 4,32÷9 43÷89,5 100 W mon. 1/2” 1/2” 33 19 200
    EM 9-E.D3 4,32÷9 43÷89,5 100 W mon. 3/4” 1/2” 18 - 360
    EM 12-E.D6 5÷12,07 49,8÷120 100 W mon. 1” 1” 12 - 360
    EM 12-E.D3 5÷12,07 49,8÷120 100 W mon. 1/2” 1/2” 22 11 360
    EM 12/L-E.D6 5÷12,07 49,8÷120 100 W mon. 1” 1” 12 - 360
    EM 12/L-E.D3 5÷12,07 49,8÷120 100 W mon. 1/2” 1/2” 22 11 360
    EM 16-E.D3 8÷16,1 80÷160 110 W mon. 3/4” 1/2” 29 28 360
    EM 16-E.D4 8÷16,1 80÷160 110 W mon. 3/4” 3/4” 18 - 360
    EM 18-E.D6 9,9÷17 99÷169 185 W mon. 1” 1” 11 - 360
    EM 18-E.D3 9,9÷17 99÷169 185 W mon. 1/2” 1/2” 27 14 360
    EM 18/L-E.D6 9,9÷17 99÷169 185 W mon. 1” 1” 11 - 360
    EM 18/L-E.D3 9,9÷17 99÷169 185 W mon. 1/2” 1/2” 27 14 360
    EM 26-E.D6 12,9÷24,6 129÷245 220 W mon. 1” 1” 20 - 360
    EM 26-E.D3 12,9÷24,6 129÷245 220 W mon. 3/4” 1/2” 53 - 360
    EM 26-E.D4 12,9÷24,6 129÷245 220 W mon. 3/4” 3/4” - 28 360
    EM 35-E.D7 18,9÷32,1 188÷320 370 W mon. 1 1/4” 1 1/4” 18 - 360
    EM 35-E.D4 18,9÷32,1 188÷320 370 W mon. 3/4” 3/4” 46 26 360

     

    Dimensions (mm):

     

    dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) D1 (mm) E (mm) F(Ø mm) N* (mm) O* (mm)
    EM 3-E 250 215 320 90 160 80 410 145
    EM 6-E 280 247 342 90 195 80 410 145
    EM 9-E 280 247 417 40÷140 195 90 445 145
    EM 12-E 230 285 483 60÷125 232 114 485 240
    EM 12/L-E 230 285 633 60÷275 232 114 485 240
    EM 16-E 310 282 480 60÷150 215 108 465 210
    EM 18-E 275 340 550 60÷150 274 114 540 240
    EM 18/L-E 275 340 675 60÷275 274 114 540 240
    EM 26-E 360 350 750 100÷265 275 140 550 240
    EM 35-E 420 423 880 120÷310 350 140 740 260

     

    The dimensions are relative to the burner ramp from 20 mbar installed.

     

    Mounting flange and Weight:

     

    flangia

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm)

    Weight (kg)

    EM 3-E 85 135÷160 M8 170 144

    11

    EM 6-E 85 135÷160 M8 170 144 12.5
    EM 9-E 95 135÷160 M8 180 154 12.5
    EM 12-E 120 155÷210 M8 180 180 11
    EM 12/L-E 120 155÷210 M8 180 180 16
    EM 16-E 115 150÷200 M8 166 166 16
    EM 18-E 120 155÷210 M8 180 180 15.5
    EM 18/L-E 120 155÷210 M8 180 180 23
    EM 26-E 155 172÷225 M10 205 205 30
    EM 35-E 155 172÷225 M10 205 205 44
  • Em ST "Domestic Line"
    • Single-stage burners with possibility of external air intake.
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation.
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • Combustion head control.
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation

    • Easy installation thanks to the universal perforation mobile flange.

    Accessories available upon request

    • Accessory set kit

    Certification

    • Em ST burners are certified EC.

     

    Characteristics circulator:

    Curva em-st

     

    Curva em-st 2

     

    Model Flow (m3/h) Power (kW)   Motor   (230V~50Hz) Network attack (Ø) Gauge valve  (Ø) Min. Pres. Nat. Gas (mbar) Min. Pres. G.P.L. (mbar) Pres.max. (mbar)
    EM 3 ST-E D1 1,61÷3,52 16÷35 100 W mon. 1/2” 1/2” 12,5 10,5 65
    EM 3 ST-E D2 1,61÷3,52 16÷35 100 W mon. 1/2” 1/2” 12,5 - 200
    EM 3 ST-E D3 1,61÷3,52 16÷35 100 W mon. 3/4” 1/2” 11 - 360

     

    Dimensions (mm):

     

    dimensioni

    (*): The dimensions are relative to the burner ramp from 20 mbar installed.

     

    Mounting flange and Weight:

     

    flangia

     

    Model Weight (body + gas train) (kg)
    EM 3 ST-E D1 11 + 2
    EM 3 ST-E D2 11 + 1,5
    EM 3 ST-E D3 11 + 2
  • Em/2-E "Domestic Line"
    • Two-stage burners.
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. Em16/2-E - Em 26/2-E - a conversion kit is necessary).
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge (mod. Em 26/2-E - Em 40/2-E).
    • Easy installation thanks to the universal perforation mobile flange.

    Accessories available upon request

    • Accessory set kit.
    • Methane to LPG conversion kit (for mod. Em 16/2-E - Em 26/2-E).
    • Valve seal control kit.

    Certification

    • Em/2-E burners are certified EC.

     

    Characteristics circulator:

     

    Curva em-2-e

     

    Model Flow (m3/h) Power (kW) Motor  (230V~50Hz) Network attack  (Ø) Gauge valve (Ø) Min. Pres. Nat. Gas (mbar) Min. Pres. G.P.L. (mbar) Press. max. (mbar)
    EM 9/2-E.D3 4,3÷9 43÷89,5 100 W mon. 3/4” 1/2” 18 19 360
    EM 16/2-E.D3 5,5÷15,3 55÷153 150 W mon. 3/4” 1/2” 28 27 360
    EM 16/2-E.D4 5,5÷15,3 55÷153 150 W mon. 3/4” 3/4” 19 - 360
    EM 18/2-E.D6 9,9÷17 99÷169 185 W mon. 1” 1” 12 - 360
    EM 18/2-E.D3 9,9÷17 99÷169 185 W mon. 3/4” 1/2” 23 14 360
    EM 26/2-E.D6 9÷23,2 90÷231 220 W mon. 1” 1” 18 - 360
    EM 26/2-E.D3 9÷23,2 90÷231 220 W mon. 3/4” 1/2” 43 - 360
    EM 26/2-E.D4 9÷23,2 90÷231 220 W mon. 3/4” 3/4” - 31 360
    EM 40/2-E.D7 11,5÷39,2 115÷390 370 W mon. 1 1/4” 1 1/4” 23 - 360
    EM 40/2-E.D4 11,5÷39,2 115÷390 370 W mon. 3/4” 3/4” 62 32 360

     

    Dimensions (mm):

     

    Dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) E (mm) F (Ø mm) N* (mm) O* (mm)
    EM 9/2-E 280 247 417 40÷140 195 90 515 195
    EM 16/2-E 310 282 480 60÷150 215 108 535 210
    EM 18/2-E 275 340 675 60÷275 274 114 640 240
    EM 26/2-E 360 350 750 100÷265 275 140 650 240
    EM 40/2-E 420 423 880 120÷310 350 140 835 260

     

    *: The dimensions are relative to the burner ramp from 20 mbar installed.

     

     

    Mounting flange and Weight:


    Flangia

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm) Weight (kg)
    EM 9/2-E 95 140÷180 M8 180 154 14
    EM 16/2-E 115 150÷200 M8 166 166 18
    EM 18/2-E 120 155÷210 M8 180 180 25
    EM 26/2-E 155 172÷225 M10 205 205 31
    EM 40/2-E 155 172÷225 M10 205 205 44
  • Em/M-E "Domestic Line"
    • Two-stage progressive burners.
    • Possibility of continuous modulation operation with the application of the modul. kit
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. Em 16/M-E - Em 26/M-E  - a conversion kit is necessary).
    • Gas ramp with dual pneumatic valve and built-in stabiliser.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge (mod. Em 26/M-E).
    • Easy installation thanks to the universal perforation sliding flange.

    Accessories available upon request

    • Accessory set kit.
    • Modul.(temperature/pressure) kit for continuous modulation.
    • Methane to LPG conversion kit (for mod. Em 16/M-E - Em 26/M-E).
    • Valve seal control kit.

    Certification

    • Em/M-E burners are certified EC.

     

    Characteristics circulator:

    Curva em-m-e

     

     

    Model Flow (m3/h) Power (kW) Motor  (230V~50Hz) Network attack  (Ø) Gauge valve (Ø) Min. Pres. Nat. Gas (mbar) Min. Pres. G.P.L. (mbar) Press. max. (mbar)
    EM 16/M-E.D4 5,5÷15,3 55÷153 150 W mon. 3/4” 3/4” 17 22 360
    EM 26/M-E.D7 9÷23,2 90÷231 220 W mon. 1 1/4” 1 1/4” 15 - 360
    EM 26/M-E.D4 9÷23,2 90÷231 220 W mon. 3/4” 3/4” - 30 360
    EM 26/M-E.D5 9÷23,2 90÷231 220 W mon. 3/4” 3/4” 25 - 360
    EM 40/M-E.D7 11,5÷39,2 115÷390 370 W mon. 1 1/4” 1 1/4” 18 - 360
    EM 40/M-E.D4 11,5÷39,2 115÷390 370 W mon. 3/4” 3/4” - 25 360
    EM 40/M-E.D5 11,5÷39,2 115÷390 370 W mon. 3/4” 3/4” 45 - 360

     

    Dimensions (mm):

     

    Dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) E (mm) F (Ø mm) N* (mm) O* (mm)
    EM 16/M-E 310 282 480 60÷150 215 108 535 210
    EM 26/M-E 360 350 750 100÷265 275 140 650 240
    EM 40/M-E 420 423 880 120÷310 350 140 740 290

    Mounting flange and Weight:

     

    Flangia

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm) Weight (kg)
    EM 16/M-E 115 150÷200 M8 166 166 18
    EM 26/M-E 155 172÷225 M10 205 205 30
    EM 40/M-E 155 172÷225 M10 205 205 44
  • Pm/M-E "Industrial Line"
    • Two-stage progressive burners.
    • Possibility of continuous modulation operation with the application of the modul. kit
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Standard valve seal control in models 310 and 430.
    • Shock-resistant electrical panel.
    • Can be combined with various types of ramps for ultimate versatility.
    • Supplied in two boxes (Burner+Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge.
    • Easy installation thanks to the universal perforation sliding flange.

    Accessories available upon request

    • Accessory set kit.
    • Modul.(temperature/pressure) kit for continuous modulation.

    Certification

    • Pm/M-E burners are certified EC.

     

    Characteristics circulator:

     

    campo di lavoro

     

    Model Flow (m3/h) Power
    (kW)
    Motor
    (230V~50Hz)
     Network attack
    (Ø)
     Gauge  valve  
    (Ø)
    Min.P.Nat.Gas
    (mbar)
    Min.Pr.G.P.L.
    (mbar)
    Press.max.
    (mbar)
    310 PM/M-E.F10 94÷290 940÷2.900 5.500 W tri. DN100 DN100 28 - 360
    310 PM/M-E.F8 94÷290 940÷2.900 5.500 W tri. DN65 DN65 67 - 360
    310 PM/M-E.F8 94÷290 940÷2.900 5.500 W tri. DN65 DN65 - 25 360
    430 PM/M-E.F10 110÷430 1.100÷4.275 9.200 W tri. DN100 DN100 29 - 360
    430 PM/M-E.F8 110÷430 1.100÷4.275 9.200 W tri. DN65 DN65 99 - 360
    430 PM/M-E.F8 110÷430 1.100÷4.275 9.200 W tri. DN65 DN65 - 30 360

     

    Dimensions (mm):

     

    dimensioni

     

    Model A (mm) B* (mm) C (mm) D (mm) E (Ø mm)
    310 PM/M-E 1.710 855 700 250÷550 256
    430 PM/M-E 1.760 855 700 250÷600 303

     

    *: The dimensions are relative to the burner ramp with the likes largest installed.

     

    Mounting flange and Weight:

     

    flangia

     

    Modello F (Ø mm) H (mm) L (mm) M (mm) N (mm) Weight (kg)
    310 PM/M-E 270 235 M16 320 320 173
    410 PM/M-E 320 380÷440 M16 400 400 238
  • Lmb G "Industrial Line"
    • Two-stage progressive burners with short nozzle distribution (mod. BC) and long nozzle distributor (mod. BL).
    • Possibility of continuous modulation operation with the application of the modul. kit
    • Suitable for pressurised boilers.
    • For methane gas operation.
    • Low emissions.
    • Combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Standard valve seal control in models 1,300 and 2,000.
    • Shock-resistant electrical panel.
    • Supplied in two boxes (Burner+Gas ramp).

    Installation and maintenance

    • Easy installation and maintenance thanks to the full inspection hinge.

    Accessories available upon request

    • Accessory set kit.
    • Modul.(temperature/pressure) kit for continuous modulation.
    • Valve seal control kit in models 300, 450, 700, 1000.

    Certification

    • Lmb G burners are certified EC.

     

     

    curve lmb g

     

    Model burner  
    NATURAL GAS

    Flow (m3/h)

    Power 
    (kW)

    Motor
    (230V~50Hz)

    Network attack (Ø)

     Gauge valve (Ø)

    Min.Pr.Nat.Gas
    (mbar)

    Press. max.(mbar)

    LMB G 300 (K 1”-125) 11,6÷33,9 110÷320 370 W mon. 1” 1” 26 500
    LMB G 300 (K 1”-225) 11,6÷33,9 110÷320 370 W mon. 1” 1 1/2” 20 500
    LMB G 300 (D 1”-300) 11,6÷33,9 110÷320 370 W mon. 1” 1” 32 360
    LMB G 450 (K 1”-125) 14,8÷48,7 140÷460 370 W mon. 1” 1” 30 500
    LMB G 450 (K 1”-225) 14,8÷48,7 140÷460 370 W mon. 1” 1 1/2” 20 500
    LMB G 450 (D 1”-700) 14,8÷48,7 140÷460 370 W mon. 1” 1 1/2” 21 360
    LMB G 700 BC - K 1” 14,0÷79,0 135÷748 740 W tri. 1” 1” 58 500
    LMB G 700 BL - K 1” 14,0÷79,0 135÷748 740 W tri. 1” 1” 58 500
    LMB G 700 BC - K 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 500
    LMB G 700 BL - K 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 500
    LMB G 700 BC - D 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 360
    LMB G 700 BL - D 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 360
    LMB G 1000 BC - K 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 35 500
    LMB G 1000 BL - K 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 35 500
    LMB G 1000 BC - K 2” 16,0÷103,0 152÷979 1.100 W tri. 2” 2” 20 500
    LMB G 1000 BL - K 2” 16,0÷103,0 152÷979 1.100 W tri. 2” 2” 20 500
    LMB G 1000 BC - S 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 18 600
    LMB G 1000 BL - S 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 18 600
    LMB G 1300 - K 1 1/2” 25,0÷136,5 237÷1.296 2.200 W tri. 1 1/2” 1 1/2” 50 500
    LMB G 1300 - K 2” 25,0÷136,5 237÷1.296 2.200 W tri. 2” 2” 22 500
    LMB G 1300 - S 2” 25,0÷136,5 237÷1.296 2.200 W tri. 2” 2” 14 600
    LMB G 1300 - S 1 1/2” 25,0÷136,5 237÷1.296 2.200 W tri. 1 1/2” 1 1/2” 19 600
    LMB G 2000 - S 1 1/2” 36,5÷202 336÷1.918 3.000 W tri. 1 1/2” 1 1/2” 40 600
    LMB G 2000 - K 2” 36,5÷202 336÷1.918 3.000 W tri. 2” 2” 45 500
    LMB G 2000 - S 2” 36,5÷202 336÷1.918 3.000 W tri. 2” 2” 30 600
    LMB G 2000 - S DN 65 36,5÷202 336÷1.918 3.000 W tri. DN 65 DN 65 18 700

     

     

    Dimensions (mm):

     

    dimensioni

     

    *: The dimensions are relative to the burner ramp with the likes largest installed.

     

    Model A* (mm) B (mm) C (mm) D (mm) E (Ø mm)
    LMB G 300 805 340 370 230 124
    LMB G 450 805 340 370 230 138
    LMB G 700 BC 950 370 540 235 166
    LMB G 700 BL 950 370 540 325 166
    LMB G 1000 BC 850 370 540 230 196
    LMB G 1000 BL 850 370 540 350 196
    LMB G 1300 1.070 440 620 340 232
    LMB G 2000 1.070 440 620 340 244

    Mounting flange and Weight:

     

    flangia

     

    Model G (Ø mm) H (Ø mm) L (mm) M (mm) N (mm) Weight (kg)
    LMB G 300 135 194÷234 M12 216 216 18
    LMB G 450 150 194÷234 M12 216 216 18
    LMB G 700 BC 180 246÷286 M12 268 268 30
    LMB G 700 BL 180 246÷286 M12 268 268 30
    LMB G 1000 BC 205 246÷286 M12 268 268 31
    LMB G 1000 BL 205 246÷286 M12 268 268 31
    LMB G 1300 255 294÷334 M12 316 316 45
    LMB G 2000 255 294÷334 M12 316 316 48

© Copyright Lamborghini Calor 2014. All Rights Reserved.
Lamborghini Calor S.p.A. - Via Statale, 342 - C.P. 46 - 44047 Dosso - FE - Italy - UNI EN ISO 9001 Certified Company
Capitale Sociale € 827.112,00 int. vers. - Cod. Fisc. - P.Iva e Reg. Impr. Ferrara n° 00173420381 Sole Shareholder Management and coordination of Ferroli S.p.A.