Floor Standing Boilers Cast Iron

  • Big FK "unassembled"
    • Floor-standing boilers designed for heating medium-sized and large systems.
    • High-quality cast iron boiler body with components to be assembled during boiler installation in the central heating, for 3-stage combustion process with fire-tube.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90\%.
    • Operation with light oil and gas burners.
    • Ideal for operation with low temperature systems (35°C).
    • Boiler plate designed for burner mounting.
    • Extra-thick insulation against heat dispersion.
    • Control panel with control and operating instruments.
    • IP X0D protection rating.

    Certifications

    • Bia FK boilers are certified EC.
  • EL_DB Condensing
    • Floor-standing boiler designed for domestic and residential heating, with light oil blower burner (not supplied with the boiler, to be ordered separately).
    • Condensing heat regenerator.
    • Cast iron boiler body for 3-stage combustion process with fire-tube firebox.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 103\%.
    • Designed for connection to an external 130-litre capacity stainless steel domestic hot water cylinder, also to be positioned beneath the boiler.
    • Boiler body insulation consisting of a thick fibreglass blanket, covered by an aluminium mesh flame-proof film against heat dispersion.
    • Available with Basic control panel or with advanced Digit control panel (to be selected at the time of order).

     

    How to order EL_DB 32 condensing ?
    Order separately:boiler, burner, control panel and any other accessories required such as water cylinder, sensors, hydraulic connections, etc. You must order at least one boiler and the basic control panel.

    Description of Accessories

    • Basic Control Panel: Simple analogue control panel for boiler operation with the burner. Suitable for use in heating only.
    • Digit Control Panel: Advanced digital control panel for complete control of both boiler and system. Digital control panel with multi-function backlit graphic display for easy parameter set-up. Can be connected to an external sensor (on request) for climate control, a water cylinder sensor (on request), a CRM type remote control and a zone management control unit (on request).
    • 130-litre stainless steel cylinder
    • Hydraulic connection kit for EL_DB 32 Condensing-water cylinder (code 08524840)
    • Soundproofing bonnet
    • Eco 3 light oil burner (code 00840005)

     

    Detail recuperator

     

    dettaglio recuperatore

     

    Basic Control Panel

     

    Cruscotto base

     

    Simple analog instrument panel for the operation of the boiler with the burner. Suitable for use in heating only.

     

    Digit Control Panel

     

    Cruscotto Digit

     

    Technical data

     

    EL_DB 32 Condensing U.M.  
    Number of elements - 3
    Heat capacity (min - max) kW 16,3 - 33,0
    Heat output (80-60 °C) (min - max) kW 16,0 - 32,0
    Heat output (50-30 °C) (min - max) kW 17,0 - 33,8
    Performance 80-60 °C (Pmin - Pmax) % 97,9 - 97,1
    Performance 50-30 °C (Pmin - Pmax) % 103,9 - 102,7
    Performance 30% % 103,6
    Energy efficiency directive 92/42 EEC - -
    Operating pressure heating (min - max) bar 0,8 - 3,0
    Maximum temperature heating °C 95
    Heating water content l 21
    Capacity expansion tank heating l 8
    Sanitary water content (with kit kettle) l 130
    DHW flow rate ΔT 30 °C (with kit kettle) l/10 min 250
    DHW flow rate ΔT 30 °C (with kit kettle) l/h 850
    Degree of protection IP X0D
    Supply Voltage V/Hz 230 / 50
    Electrical power consumption W 320
    Empty weight Kg 183
    Pressure drop flue gas side mbar 0,11

     

    Connections and dimensions

     

    dimensioni

     

    A: 400 mm

    a1 (System delivery): 1''

    a2 (System return): 1''

    a5: 105 mm

    a6 (Domestic hot water outlet): 3/4''

    a7 (Recirculation): 3/4''

    a8 (Domestic hot water inlet): 3/4''

  • EL_DB
    • Floor-standing boilers designed for domestic and residential heating, with blower burners (not supplied with the boiler, to be ordered separately).
    • Operation with light oil and gas burners.
    • Cast iron boiler body for 3-stage combustion process with fire-tube firebox.
    • Combustion chamber and heat exchanger designed to guarantee efficiency levels of over 90%.
    • Designed for connection to an external domestic hot water cylinder, also to be positioned beneath the boiler (mod. 32 and 47).
    • Boiler body insulation consisting of a thick fibreglass blanket, covered by an aluminium mesh flame-proof film against heat dispersion.
    • Available with Basic control panel or with advanced Digit control panel (to be selected at the time of order).

     

    How to order EL_DB?
    Order separately:boiler, burner, control panel and any other accessories required such as water cylinder, sensors, hydraulic connections, etc. You must order at least one boiler and the basic control panel.

     

    Basic control panel

    Simple analog instrument panel for the operation of the boiler with the burner. Suitable for use in heating only.

     

    Cruscotto base

     

    Digit control panel

    Advanced digital dashboard for the complete management of the boiler and the system. Digital control panel with graphic display Multifunction backlit for easy parameter setting. You can connect an external sensor (optional) for a climate control, a probe kettle (on request), a remote control type of CRM and a central management areas (on request).

     

    Cruscotto Digit

     

    Technical data

     

    EL_DB U.M. 32 47 63 80 98
    Number of elements - 3 4 5 6 7
    Heat capacity (min - max) kW 17 - 34,9 34,3 - 51,6 45,8 - 69 59 - 87,8 75 - 106,5
    Heat output (min - max) kW 16 - 32 32 - 47 43 - 63 55 - 80 70 - 98
    Performance Pmax (80-60 °C) % 91,6 91,6 91,6 91,8 92,1
    Performance 30% % 94,1 93,9 93,7 93,4 93,3
    Energy efficiency directive 92/42 EEC - * * * * * * * * * *
    Operating pressure heating (min - max) bar 0,8 - 6 0,8 - 6 0,8 - 6 0,8 - 6 0,8 - 6
    Maximum temperature heating °C 95 95 95 95 95
    Heating water content litri 12,5 17 21,5 26 31
    Degree of protection IP 41 41 41 41 41
    Supply Voltage V/Hz 230/50 230/50 230/50 230/50 230/50
    Empty weight kg 133 175 216 259 301
    Pressure drop flue gas side mbar 0,05 0,2 0,3 0,5 0,6

     

    Dimensions (mm)

     

    Dimensioni1

    EL_DB with Basic control panel.

     

    Dimensioni2

    EL_DB with Digit control panel.

     

     

    Dimensioni3

    EL_DB with Digit control panel and kettle.

     

     

    EL_DB A a1 a2 a3 a4 a5 a6 a7 a8
    32 400 1" 1/2 1" 1/2 1/2" 120-130 105 3/4" 3/4" 3/4"
    47 500 1" 1/2 1" 1/2 1/2" 120-130 105 3/4" 3/4" 3/4"
    63 600 1" 1/2 1" 1/2 1/2" 120-130 105 3/4" 3/4" 3/4"
    80 700 1" 1/2 1" 1/2 1/2" 120-130 105 3/4" 3/4" 3/4"
    98 800 1" 1/2 1" 1/2 1/2" 120-130 125 3/4" 3/4" 3/4"

     

    a1. System delivery.

    a2. System return.

    a3. Boiler drain.

    a4. Flue connection.

    a5. Connection burner.

    a6. Kettle delivery.

    a7. Kettle return.

    a8. Circolatore caldaia.