Login

User Name  
Password  
Create account

Who is online

We have 45 guests and no members online

Discontinued wall-hung atmospheric boilers

  • INOVA E
    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) for heating and hot water production, high efficiency (2 stars)
    • Electronically controlled single-sensor system continuous modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC TOP.
    • High-efficiency copper heat exchanger
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Concealed instruments to control and adjust the unit.
    • Designed to accommodate time programmer.
    • Instant heat exchanger for domestic hot water.
    • Hydraulic 3-way valve
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS TOP.
    • IP X4D protection rating.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy front access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • The INOVA E boiler is certified EC.

    Range

    • INOVA E MC W TOP heating and domestic hot water production, open-vented, high efficiency.
    • INOVA E MCS W TOP heating and domestic hot water production, room-sealed, high efficiency.
  • INOVA L
    • High efficiency open-vented boilers designed for heating and domestic hot water production.
    • Designed for possible operation with low temperature systems.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting.
    • High-efficiency copper heat exchanger
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Concealed instruments to control and adjust the unit.
    • Designed to accommodate time programmer
    • Instant plate heat exchanger for domestic hot water.
    • Hydraulic 3-way valve.
    • By-pass
    • Designed to accommodate remote kit
    • IP X4D protection rating.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits (on request).
    • Easy maintenance thanks to the easy front access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • The hydraulic connection kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • INOVA L boilers are certified EC.
  • XILO T
    • Open-vented boiler (mod. M) and room-sealed boiler (mod. MS) designed for heating.
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MS.
    • Electronically controlled proportional modulation on the heating circuit
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. M.
    • High-head circulation pump
    • 8-litre expansion vessel
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MS)
    • IP X4D protection grade
    • XILO T 24 boilers are designed to be combined with PAC B water cylinders.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO T boilers are certified EC.
  • XILO 'compact bithermal'
    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and domestic hot water production.
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC
    • High-efficiency bithermal copper heat exchanger.
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod.MCS)
    • Priority flowmeter.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • IP X4D protection rating.
    • Hydraulic connections supplied with the product

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Type DPO/B polyphosphate feeder
    • See the Accessories section for further details.

    Certification

    • XILO boilers are certified EC.
  • XILO D

    XILO D 'compact monothermal'

    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and domestic hot water production
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Instant plate heat exchanger for domestic hot water
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC.
    • By-pass
    • High-head circulation pump
    • 8-litre expansion vessel
    • Electric three-way diverter valve
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS)
    • Priority flowmeter
    • IP X4D protection grade
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO D boilers are certified EC.
  • VELA XN "wall-hung with water cylinder"
    • Open-vented boiler (mod. MB) and room-sealed boiler (mod. MBS) for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • Designed for possible operation with low temperature systems.
    • Electronically controlled continuous modulation on the DHW circuit and heating circuit.
    • 60-litre stainless steel storage cylinder.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MB
    • Anti-Legionella function
    • Copper heat exchanger
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre heating circuit expansion vessel.
    • 2-litre DHW circuit expansion vessel.
    • Instruments to control and adjust the unit.
    • Electric three-way valve.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MBS.
    • By-pass.
    • IP X4D protection grade
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • VELA XN boilers are certified EC.
  • ALMA "wall-hung with water cylinder"
    • Open-vented boilers (mod. MB) and room-sealed boiler (mod. MBS) for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • 50-litre stainless steel storage cylinder.
    • Copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Combustion chamber insulated with ceramic fibre.
    • Electronic ignition with ionisation flame control.
    • Electronically controlled continuous modulation on the DHW circuit and heating circuit.
    • Designed for possible operation with low temperature systems.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MBS.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MB.
    • Slow opening gas valve.
    • 8-litre heating circuit expansion vessel.
    • 2-litre DHW circuit expansion vessel.
    • High-head circulation pump.
    • Electric three-way valve.
    • Control panel.
    • Heating and DHW temperature control.
    • Flue gas inspection points supplied as standard in the boiler (mod.MBS)
    • Fault display.
    • Frost protection function.
    • Post-circulation function.
    • Anti-Legionella function.
    • By-pass.
    • IP X4D protection grade
    • Designed to accommodate digital time programmer (mod. MBS).
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • ALMA boilers are certified EC.
  • NINFA 'compact monothermal'
    • Open-vented boiler (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C.
    • Designed for possible operation with low temperature systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. MC.
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel (mod. 24) 10-litre capacity (mod. 32).
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flowmeter, 3-way valve and by-pass.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.
    • Functions: frost protection, post-circulation, solar, air purge and pre-heat.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Frost protection kit, to protect the DHW circuit, for operation up to -15°C of the boiler.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of NINFA open-vented version boilers.
    • External sensor.
    • See the Accessories section for further details.

    Certification

    • NINFA boilers are certified EC.
  • NINFA T
    • Open-vented boiler (mod. M) and room-sealed boiler (mod. MS) designed for heating, high efficiency (3 stars for the room-sealed versions).
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C.
    • Designed for possible operation with low temperature systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MS.
    • Electronically controlled proportional modulation on the heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting in mod. M.
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod. MS).
    • Priority flowmeter and by-pass.
    • Designed to accommodate possible external water cylinder with a 3-way valve.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.
    • Functions: frost protection, post-circulation and air purge.
    • NINFA T boilers are designed to be combined with PAC S water cylinders.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of NINFA T open-vented version boilers.
    • External sensor.
    • See the Accessories section for further details.

    Certification

    • NINFA T boilers are certified EC.
  • NOVA DM
    • Room-sealed boilers designed for heating and hot water production, high efficiency (3 stars for the room-sealed versions).
    • Stainless steel aspirated burner for all gas types.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water production with 5-litre micro storage tank insulated with polyurethane foam.
    • Electronic ignition with ionisation flame control.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • Room-sealed combustion circuit with electric flue gas exhaust fan.
    • Slow opening gas valve.
    • 8-litre expansion vessel.
    • Electric three-way valve.
    • Adjustable by-pass.
    • Designed for operation with low temperature systems.
    • Designed for control and adjustment via remote control.
    • Designed for operation with external sensor.
    • IP X4D protection rating.
    • Functions: frost protection, post-circulation, solar, air purge and pre-heat.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • NOVA DM boilers are certified EC.
  • Ninfa N "compact monothermal"
    • Open-vented boilers (mod. MCA) and room-sealed boilers (mod. MCS) designed for heating and hot water production, high efficiency.
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for possible operation with low temperature systems.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. MCS).
    • Combustion chamber insulated with ceramic fibre.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. MCA).
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel (mod. 24) 10-litre capacity (mod. 32).
    • Slow opening gas valve.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flowmeter, 3-way valve and by-pass.
    • Functions: air purge, pre-heat and post-circulation.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix and external sensor.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of Ninfa N open-vented version boilers.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG open-vented boilers.

    Certification

    • Ninfa N boilers are certified EC.
  • Ninfa N T
    • Open-vented boilers (mod. TCA) and room-sealed boilers (mod. TCS) designed for heating, high efficiency.
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C.
    • Designed for possible operation with low temperature systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Stainless steel aspirated burner for all gas types.
    • Electronic ignition with ionisation flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. TCS).
    • Combustion chamber insulated with ceramic fibre.
    • Electronically controlled continuous modulation on the heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. TCA).
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel.
    • Electric three-way valve for possible management of a water cylinder.
    • Water cylinder connectors supplied as standard.
    • Slow opening gas valve.
    • Flue gas inspection points supplied as standard in the boiler (mod. TCS).
    • Priority flowmeter.
    • Automatic by-pass.
    • Functions: air purge and post-circulation.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • External sensor and water cylinder sensor.
    • Box zone Mix.
    • Windproof kit, indispensable for operation outdoors
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG boilers

    Certification

    • Ninfa N T boilers are certified EC.
  • iXtech
    • Open-vented boilers (mod. MC) and room-sealed boiler (mod. MCS) designed for heating and hot water production, high efficiency, even at minimum power.
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for operation with low temperature systems.
    • Designed for control and adjustment via remote control.
    • Functions: frost protection, post-circulation, air purge and pre-heat.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water production with 5-litre micro storage tank, covered with high density polystyrene.
    • Stainless steel aspirated burner for all gas types.
    • Combustion chamber insulated with ceramic fibre.
    • Room-sealed combustion circuit with electric flue gas exhaust fan, self-regulating via pressure transducer (mod.MCS).
    • Microprocessor-controlled printed circuit board designed for possible external sensor.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Electronic ignition with ionisation flame control.
    • Slow opening gas valve.
    • Circulation pump on heating circuit.
    • 8-litre expansion vessel.
    • 0,15-litre DHW expansion vessel.
    • Electric three-way valve.
    • Automatic by-pass.
    • IP X5D protection rating.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • External sensor.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG open-vented boilers.

    Certification

    • iXtech boilers are certified EC.
  • Ninfa N Low NOx "Ultra Low Emissions"
    • Open-vented boilers (mod. MCA) and room-sealed boilers (mod. MCS) designed for heating and hot water production, high efficiency.
    • Ultra compact size (-13\% compared to traditional boiler dimensions).
    • Operation outdoors in partially protected settings up to -5°C as standard and up to -15°C with the help of the frost protection heating elements kit (on request).
    • Designed for possible operation with low temperature systems.
    • Designed to accommodate solar systems: designed for domestic hot water production combined with solar panel systems.
    • Water cooled burner affording ultra low NOx emissions, made of stainless steel, for all gas types.
    • NOx emission class = 5 (.<70 mg/kWh).
    • High-efficiency monothermal primary copper heat exchanger.
    • Instant heat exchanger for domestic hot water.
    • Electronic ignition with ionisation flame control.
    • Digital control panel with multi-function backlit graphic display for easy and correct parameter set-up.
    • Room-sealed combustion circuit with electric flue gas exhaust fan (mod. MCS).
    • Combustion chamber insulated with ceramic fibre.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • FLUE CONTROL safety circuit breaker against the backflow of burnt gases into the setting (mod. MCA).
    • Self-diagnosis check with faults shown on illuminated display.
    • High-head circulation pump.
    • Circulation pump anti-seizure device.
    • 8-litre expansion vessel.
    • Slow opening gas valve.
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS).
    • Priority flowmeter, 3-way valve and by-pass.
    • Functions: air purge, pre-heat and post-circulation.
    • IP X5D protection rating.
    • Possibility of connecting the room thermostat or remote control.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Hydraulic connection kits.
    • Remote programmable timer, modulating, with zone management possibility.
    • Frost protection heating elements for protection up to -15°C.
    • Box zone Mix and external sensor.
    • Windproof kit, indispensable for operation outdoors in partially protected settings of Ninfa N open-vented version boilers.
    • See the Accessories section for further details.

    Accessories supplied

    • Methane to LPG conversion kit in LPG boilers

    Certification

    • Ninfa N Low NOx boilers are certified EC.
  • Taura
    • Open-vented boilers (mod.MC) and room-sealed boilers (mod. MCS), bithermal, designed for heating and instant hot water production, high efficiency.
    • Solar function (mod. 24).
  • NOVA
    • High efficiency room-sealed boiler, bithermal, designed for heating and instant domestic hot water production.
    • Hydraulic connections supplied as standard.
  • NOVA D
    • High efficiency room-sealed boilers, monothermal, designed for heating and domestic hot water production.
    • Hydraulic connections supplied as standard.
  • XILO N T
    • Room-sealed boiler designed for heating, high efficiency (3 stars)
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MS.
    • Electronically controlled proportional modulation on the heating circuit
    • High-head circulation pump
    • 8-litre expansion vessel
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MS)
    • IP X4D protection grade
    • XILO T 24 boilers are designed to be combined with PAC B water cylinders.
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO T boilers are certified EC.
  • XILO N
    • Room-sealed boiler designed for heating and hot water production, high efficiency (3 stars)
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit.
    • High-efficiency bithermal copper heat exchanger.
    • Electronic ignition with ionisation flame control.
    • Stainless steel aspirated burner for all gas types.
    • Slow opening gas valve.
    • Combustion chamber insulated with ceramic fibre.
    • High-head circulation pump.
    • 8-litre expansion vessel.
    • Instruments to control and adjust the unit.
    • Flue gas inspection points supplied as standard in the boiler (mod.MCS)
    • Priority flowmeter.
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • IP X4D protection rating.
    • Hydraulic connections supplied with the product

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • Type DPO/B polyphosphate feeder
    • See the Accessories section for further details.

    Certification

    • XILO boilers are certified EC.
  • XILO N D
    • Room-sealed boiler designed for heating and hot water production, high efficiency (3 stars)
    • Designed for possible operation with low temperature systems.
    • Compact size (-20\% compared to traditional boiler dimensions)
    • High-efficiency primary copper heat exchanger
    • Instant plate heat exchanger for domestic hot water
    • Electronic ignition with ionisation flame control
    • Stainless steel aspirated burner for all gas types
    • Room-sealed combustion circuit with electric flue gas exhaust fan in mod. MCS.
    • Electronically controlled proportional modulation on the DHW circuit and heating circuit
    • By-pass
    • High-head circulation pump
    • 8-litre expansion vessel
    • Electric three-way diverter valve
    • Slow opening gas valve
    • Combustion chamber insulated with ceramic fibre
    • Instruments to control and adjust the unit
    • Flue gas inspection points supplied as standard in the boiler (mod. MCS)
    • Priority flowmeter
    • IP X4D protection grade
    • Hydraulic connections supplied with the product.

    Installation and maintenance

    • Easy boiler installation thanks to the template connectors and the hydraulic connection kits.
    • Easy maintenance thanks to the easy access to internal components.

    Accessories available upon request

    • The flue gas extraction/discharge kits are not supplied with the product.
    • See the Accessories section for further details.

    Certification

    • XILO D boilers are certified EC.
  • INOVA
    • Open-vented boiler (mod. C) and room-sealed boilers (mod. CS) designed for domestic hot water production, high efficiency

© Copyright Lamborghini Calor 2014. All Rights Reserved.
Lamborghini Calor S.p.A. - Via Statale, 342 - C.P. 46 - 44047 Dosso - FE - Italy - UNI EN ISO 9001 Certified Company
Capitale Sociale € 827.112,00 int. vers. - Cod. Fisc. - P.Iva e Reg. Impr. Ferrara n° 00173420381 Sole Shareholder Management and coordination of Ferroli S.p.A.