Login

User Name  
Password  
Create account

Who is online

We have 34 guests and no members online

View the products of the following categories

  • Light oil burners

  • Gas burners for industrial application

  • Gas burners

  • Low NOx burners gas

  • Fire "Standard Line"
    • Single-stage burners (Fire) and single-stage burners with pre-heater (Fire R).
    • Suitable for medium pressurisation boilers.
    • Low emissions.
    • External combustion head and air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Compact size.

    Installation and maintenance

    • Easy installation and maintenance thanks to the universal perforation mobile flange

    Accessories supplied

    • Line filter, 2 flexible hoses, nozzle and nozzle spanner, boiler insulating seal

    Accessories available upon request

    • Soundproofing bonnet
    • Soundproofing bonnet designed to accommodate external air inlet
    • External air intake cover
    • External air intake kit for room-sealed combustion

    Certification

    • Fire burners are certified EC.

     

     

    Dimensions (mm):

    dimensioni fire

     

     

    Model A (mm) B (mm) C (mm) E (mm) E (mm) F (Ø mm)
    FIRE 1 260 270 290 100 180 90
    FIRE 3 260 270 290 100 180 90
    FIRE 6 260 270 290 100 180 90
    FIRE 9 260 270 330 140 180 100
    FIRE 1R 260 270 290 100 180 90
    FIRE 3R 260 270 290 100 180 90
    FIRE 6R 260 270 290 100 180 90

     

    Mounting flange and Weight:

     

    flangia fire

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm) N (Ø mm) Weight (kg)
    FIRE 1 - 1R 95 140 140÷180 M8 180 155 9,8
    FIRE 3 - 3R 95 140 140÷180 M8 180 155 9,8
    FIRE 6 - 6R 95 140 140÷180 M8 180 155 11,3
    FIRE 9 105 140 140÷180 M8 180 155 11,3

     

    Characteristics circulator:

     

    Curva fire

     

    Curva fire 2

     

     

    Technical data:

    Model Flow (kg/h)
    Power (kW)
    Motor (230V ~ 50Hz)
    FIRE 1 1,4÷3 16,6÷35,6

    100 W mon.

    FIRE 3 1,4÷4 16,6÷47,4 100 W mon.
    FIRE 6 2,4÷5,5 28,5÷65,2 100 W mon.
    FIRE 9 4,7÷9 55,7÷106,7 100 W mon.

    FIRE 1R

    1,2÷3 14,2÷35,6 100 W mon.
    FIRE 3R 1,2÷4 14,2÷47,4 100 W mon.
    FIRE 6R 2,4÷5,5 28,5÷65,2

    100 W mon.

  • Eco "Domestic Line"
    • Single-stage burners (Eco), single-stage burners with pre-heater (Eco R) and single-stage burners with long nozzle distributor (Eco L).
    • Suitable for medium pressurisation boilers.
    • Low emissions.
    • Combustion head control.
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet and for models Eco 3 - Eco 3R - Eco 5 N - Eco 5 RN with soundproofing inside.
    • Compact size.

    Installation and maintenance

    • Easy installation and maintenance thanks to the universal perforation mobile flange (sliding from model ECO 8).

    Accessories supplied

    • Line filter, 2 flexible hoses, nozzle, nozzle spanner and boiler insulating seal.

    Certification

    • Eco burners are certified EC.

     

    Dimensions (mm):

    Dimensioni eco eco-r

     

     

    Model A (mm) B (mm) C (mm) D (mm) D1 (mm) E (mm) F (mm)
    ECO 3 250 215 320 90 - 60 80
    ECO 5N 280 247 342 90 - 195 80
    ECO 8 230 285 465 - 60÷120 232 89
    ECO 10 230 285 483 - 60÷125 232 114
    ECO 15 275 340 550 - 80÷150 274 114
    ECO 20 275 340 535 - 60÷135 214 114
    ECO 22 360 350 576 - 60÷200 275 120
    ECO 30 420 423 770 - 70÷320 350 135
    ECO 3R 250 215 320 90 - 160 80
    ECO 5R 280 247 342 90 - 195 80
    ECO 7R 280 247 410 - 40÷140 195 90

     

     

    Mounting flange and Weight:

     

    Flangia-1 eco

     

     

     

     

     

     

     

    Flangia-2 eco

    flangia-3 eco

     

    Flangia-4 eco

     

    Model G (Ø mm) H (Ø mm) L (Ø mm) M (Ø mm) N (Ø mm) Weight(kg)
    ECO 3 85 135 ÷ 160 M8 170 144 11,3
    ECO 5N 85 135 ÷ 160 M8 170 144 12,5
    ECO 8 95 127 ÷ 198 M8 160 160 12,6
    ECO 10 120 155 ÷ 210 M8 180 180 12,6
    ECO 15 120 155 ÷ 210 M8 180 180 16
    ECO 20 120 155 ÷ 210 M8 180 180 17
    ECO 22 135 160 ÷ 225 M10 225 205 23
    ECO 30 145 172 ÷ 225 M10 225 205 33,5
    ECO 10/L 120 110 ÷ 150 M8 180 180 13
    ECO 15/L 120 110 ÷ 150 M8 180 180 15
    ECO 20/L 120 110 ÷ 150 M8 180 180 15
    ECO 3R 85 135 ÷ 160 M8 170 144 11,5
    ECO 5RN 85 135 ÷ 160 M8 170 144 12,6
    ECO 7 R 95 135 ÷ 160 M8 180 154 13,6

     

     

     

     

     

     

     

     

     

     

     

     

     

    Characteristics circulator:


    Curva eco


    Curva eco 2

     

    Curva eco 3

     

  • Eco/2 "Domestic Line"
    • 2-stage burners.
    • Suitable for medium pressurisation and pressurised burners.
    • Low emissions.
    • Combustion head and air control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.

    Installation and maintenance

    • Easy installation and maintenance thanks to the universal perforation sliding flange.

    Accessories supplied

    • Line filter.
    • 2 flexible hoses.
    • 2 nozzles with the exception of mod. ECO 7/2 - ECO 15/2 - ECO 20/2.
    • Nozzle spanner.
    • Boiler insulating seal.

    Certification

    • Eco/2 burners are certified EC.

     

    Dimensions (mm):

    Dimensioni

     

     

     

    Model A (mm) B (mm) C (mm)   D (mm)  E (Ø mm) F (mm)
    ECO 15/2 275 340 685 80 ÷ 285 114 274
    ECO 20/2 275 340 700 60 ÷ 300 114 274
    ECO 22/2 360 350 576 60 ÷ 300 120 275
    ECO 30/2 420 423 770 70 ÷ 320 135 350
    ECO 40/2 420 423 790 70 ÷ 320 148 350

     

    Mounting flange and Weight:

     

    Flangia 15-20

     

    Flangia 22-30

     

    Model G (Ø mm) H (Ø mm) L (mm) M (mm) N (mm) Weight (kg)
    ECO 15/2 120 155 ÷ 210 M8 180 180 18
    ECO 20/2 120 155 ÷ 210 M8 180 180 19
    ECO 22/2 135 160 ÷ 225 M10 214 205 24
    ECO 30/2 145 172 ÷ 225 M10 214 205 35
    ECO 40/2 160 172 ÷ 225 M10 214 205 35

     

     

    Technical data:

     

    Model Flow (kg/h) Power (kW)

    Motor (230V ~ 50Hz)

    ECO 15/2 7 ÷ 14,8 83 ÷ 175,5 185 W mon.
    ECO 20/2 10 ÷ 20 118,6 ÷ 237,2 185 W mon.
    ECO 22/2 10 ÷ 23 118,6 ÷ 272,8 250 W mon.
    ECO 30/2 12 ÷ 30 142,3 ÷ 356

    370 W mon.

    ECO 40/2 22,5 ÷ 40 266,9 ÷ 474 370 W mon.
  • Eco ST "Domestic Line"
    • Room-sealed single-stage burners (Eco ST) and room-sealed single-stage burners with pre-heater (Eco R ST).
    • Suitable for medium pressurisation boilers.
    • Low emissions.
    • Combustion head control.
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.

    Installation and maintenance

    • Easy installation and maintenance thanks to the universal perforation mobile flange.

    Accessories supplied

    • Line filter, 2 flexible hoses, nozzle, nozzle spanner and boiler insulating seal.

    Certification

    • Eco ST burners are certified EC.

     

    Characteristics circulator:

     

    Curva ecoST 1


     

    Model Flow (kg/h) Power (kW) Motor (230V ~ 50Hz)
    ECO 3 ST 1,4÷3 16,6÷35,6 100 W mon.
    ECO 3 R-ST 1,2÷3 14,2÷35,6 100 W mon.
    ECO 5 RN-ST 2,6÷5 30,8÷59,3 100 W mon.

     

    Dimensions (mm):

     

    Dimensioni eco-ST

     

    Model A (mm) B (mm) C (mm) D (mm) E (mm) F (Ø mm) G (Ø mm)
    ECO 3 ST 250 215 335 90 160 80 60
    ECO 3 R-ST 250 215 335 90 160 80 60
    ECO 5 RN-ST 280 247 362 90 195 80 80

     

    Mounting flange and Weight:


    Flangia eco-ST

    Model G (Ø mm) H (Ø mm) L (Ø mm) M (Ø mm) N (Ø mm) Weight (kg)
    ECO 3ST 85 135 ÷ 160 M8 170 144 10,5
    ECO 3R-ST 85 135 ÷ 160 M8 170 144 10,7
    ECO 5RN-ST 85 135 ÷ 160 M8 170 144 11,5

     

     

     

  • Pg/2 "Industrial Line"
    • 2-stage burners.
    • Suitable for pressurised boilers.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Shock-resistant electrical panel.

    Installation and maintenance

    • Easy installation thanks to the sliding flange.
    • Simple maintenance thanks to the full inspection hinge.

    Accessories supplied

    • Line filter, 2 flexible hoses, 2 nozzles, nozzle spanner and boiler insulating seal.

    Certification

    • Pg/2 burners are certified EC.

     

    Characteristics circulator:

    Curva pg-2

     

     

     

    Curva pg-2 2

     

     

    Dimensions (mm):

     

    dimensioni

     

     

    Model A (mm) B (mm) C (mm) D (mm) E (Ø mm) F (mm)
    PG 180/2 870 700 1.640 200 ÷ 520 246 160
    PG 250/2 860 700 1.700 250 ÷ 600 304 200
    PG 300/2 860 700 1.700 250 ÷ 600 316 200

     

     

    Mounting flange and Weight:


    flangia pg2 180

    flangia pg2 250-300

     

     

    Model G (mm) H (mm) L (mm) M (mm) N (mm) Weight (kg)
    PG 180/2 260 235 M16 320 320 201
    PG 250/2 320 380 ÷ 440 M16 400 400 295
    PG 300/2 320 380 ÷ 440 M16 400 400 330
  • Pg/M "Industrial Line"
    • 2-stage progressive burners.
    • Suitable for pressurised boilers.
    • Fitted with variable profile cam.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution.
    • Designed to operate with continuous modulation with the for the modul. kit
    • Shock-resistant electrical panel.

    Installation and maintenance

    • Easy installation thanks to the sliding flange
    • Simple maintenance thanks to the full inspection hinge

    Accessories supplied

    • Line filter
    • 2 flexible hoses
    • 2 nozzles and nozzle spanner
    • Boiler insulating seal

    Accessories available upon request

    • Modul. kit for continuous modulation operation.
    • See the Accessories section for further details.

    Certification

    • Pg/M burners are certified EC.

     

    Characteristics circulator:

    Curva pg-m

     

     

    Model Flow(kg/h) Model (kW) Motor (230V ~ 50Hz)
    PG 180/M 60 ÷ 180 711,6 ÷ 2.135 4.800 W tri.
    PG 250/M 90 ÷ 250 1.067,4 ÷ 2.965 7.500 W tri.
    PG 300/M 120 ÷ 300 1.423,2 ÷ 3.558 7.500 W tri

     

     

    Dimensions (mm):

     

    dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) E (Ø mm) F (mm)
    PG 180/M 870 700 1.640 200 ÷ 520 246 160
    PG 250/M 860 700 1.700 250 ÷ 600 304 200
    PG 300/M 860 700 1.700 250 ÷ 600 316 200

    Mounting flange and Weight:


    flangia pgM-180

    flangia pgM 250-300

     

    Model G (mm) H (mm) L (mm) M (mm) N (mm) Weight (kg)
    PG 180/M 260 235 M16 320 320 201
    PG 250/M 320 380 ÷ 440 M16 400 400 295
    PG 300/M 320 380 ÷ 440 M16 400 400 330
  • Lmb LO "Industrial Line"
    • 2- and 3-stage burners with short nozzle distributor (mod. BC) and long nozzle distributor (mod. BL).
    • Suitable for pressurised boilers.
    • Low emissions.
    • Combustion head control via shutter.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Control and adjustment panel, with operating status, fault and failure code display.
    • Backlit LCD display.
    • Standard safety valve in models Lmb LO 1300 and Lmb LO 2000.
    • Pump priming function and temporary burner stop.
    • Protection against power supply voltage surges and failures.
    • Fault history menu display.
    • Display of total and partial operating hours of stages 1, 2 and 3.
    • Total fuel consumption display.
    • Flame signal intensity display.
    • Adjustable post-ventilation time.
    • IP X4D electrical protection rating.

    Installation and maintenance

    • Easy installation and maintenance thanks to the full inspection hinge and the air inlet.

    Accessories supplied

    • Line filter.
    • 2 flexible hoses.
    • 2 nozzles (mod. with 2 stages), 3 nozzles (mod. with 3 stages) and nozzle spanner.
    • Boiler insulating seal.

    Certification

    • Lmb LO burners are certified EC.

     

    Characteristics circulator:

    Curva lmb lo

     

     

    Model Flow (kg/h) Power (kW)  Motor (230V ~ 50Hz)
    LMB LO 300 9,7 ÷ 30,4 115 ÷ 360 370 W TRIF.
    LMB LO 450 11,8 ÷ 39,6 140 ÷ 470 370 W TRIF.
    LMB LO 700 BC 11,4 ÷ 59,4 135 ÷ 704 750 W TRIF.
    LMB LO 700 BL 11,4 ÷ 59,4 135 ÷ 704 750 W TRIF.
    LMB LO 1000 BC 16,1 ÷ 80,0 192 ÷ 950 1100 W TRIF.
    LMB LO 1000 BL 16,1 ÷ 80,0 192 ÷ 950 1100 W TRIF.
    LMB LO 1300 41,1 ÷ 115,0 201 ÷ 1370 2200 W TRIF
    LMB LO 2000 59,8 ÷ 166,0 452 ÷ 1976 3000 W TRIF

     

    Dimensions (mm):

     

    dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) E (Ø mm)
    LMB LO 300 480 340 370 220 220
    LMB LO 450 480 340 370 220 220
    LMB LO 700 BC 560 370 540 235 235
    LMB LO 700 BL 560 370 540 325 325
    LMB LO 1000 BC 560 370 540 230 230
    LMB LO 1000 BL 560 370 540 320 320
    LMB LO 1300 650 440 620 340 340
    LMB LO 2000 650 440 620 340 340

     

    Mounting flange and Weight:

    flangia

     

    Model G (Ø mm) H (Ø mm) L (mm) M (mm) N (mm)
    LMB LO 300 135 194 ÷ 234 M12 216 216
    LMB LO 450 150 194 ÷ 234 M12 216 216
    LMB LO 700 BC 180 246 ÷ 286 M12 268 268
    LMB LO 700 BL 180 246 ÷ 286 M12 268 268
    LMB LO 1000 BC 205 246 ÷ 286 M12 268 268
    LMB LO 1000 BL 205 246 ÷ 286 M12 268 268
    LMB LO 1300 255 294 ÷ 334 M12 316 316
    LMB LO 2000 255 294 ÷ 334 M12 316 316
  • LMB G-RE

    These are blower burners, with gas-air mixing at the combustion head and continuous modulation. They are entirely automatic and supplied with controls for maximum safety.

    They can be combined with any type of combustion chamber, whether in a vacuum or under pressure, within the operatin range envisaged.

    The burners are supplied complete with a gas supply ramp. The gas ramp is selected after careful consultation of the diagram of pressure loss depending on the mains gas pressure, on the gas flow rate required by the utility and on the back-pressure in the combustion chamber.

    All burner components are easy to inspect, without having to disconnect them form the gas supply.

     

    Technical specifications

    • Sheet steel body complete with flange for connection to the generator.
    • High performance fan.
    • Air intlet with shutters for combustion air control.
    • Electronically controlled servo-controls for air and gas control.
    • Flame display indicator light.
    • Stainless steel nozzle and combustion head.
    • Gas ramp comprising the operating and control valve, an electronically-valve seal control.
    • Air pressure gauge to check the presence of combustion air.
    • Flame presence control via photocell.
    • Gas valve seal control.
    • Electronic control and command equipment.
    • Parameter control display.
    • Diagnostics and errors display.
    • Modulation control unit.
    • Easy maintenance and access to the combustion head, which can be removed.

     

    Technical data

     

    LMB G U.M. 5500 RE 6500 RE 8300 RE 9900 RE
    Type - Modulating Modulating Modulating Modulating
    Operation - Intermittent Intermittent Intermittent Intermittent
    Control - Electronic cams Electronic cams Electronic cams Electronic cams
    Maximum heat output kW 5500 6500 8300 10600
    Minimum heat output kW 1800 2000 2700 3500
    Nox class - 1 1 1 1
    Gas category - G20 G20 G20 G20
    Maximum gas flow rate (15°C-1,013,5 mbar) m3/h 582 688 878 1122
    Minimum gas flow rate (15°C-1,013,5 mbar) m3/h 190 212 286 370
    Electrical protection rating IP X0D X0D X0D X0D
    Motor electricity supply (three-phase) V/Hz 400/50 three-phase 400/50 three-phase 400/50 three-phase 400/50 three-phase
    Auxiliary electricity supply (single-phase) V/Hz 230/50 single-phase 230/50 single-phase 230/50 single-phase 230/50 single-phase
    Motor nominal electricity consumption kW 11 15 22 28
    Transformer (voltage/secondary current) kV/mA 15/48 15/48 15/48 15/48
    Operating temperature (min/max) °C 0/40 0/40 0/40 0/40
    Noise level dbA 78 78 78 78
    Weight of burner body (without ramp) kg 325 333 475 490

     

     

    Basic Ramp: gas line diagram, referring to the basic ramp supplied with the burner

     

     

     schema impianto

     

    1. Burner

    2. Seal control pressure gauge

    3. Gas filter

    4. Butterfly valve servo-control

    5. Minimum gas pressure gauge

    6. Maximum gas pressure gauge

    7. Valve body

    8. Gas valve servo-control with stabiliser

    9. ON/OFF gas valve servo-control

    10. Gas butterfly valve

    11. Adjustable gas pilot valve

    12. ON/OFF gas pilot valve

     

     

    Dimensions (in mm)

     

    dimensioni rev

     

    Model A (mm) B (mm) C ( mm) D (mm) E1 (mm) E2 (mm) F (ᴓ mm) G (mm) H (mm) I (mm)
    DN 50 DN 65 DN 80 DN 100
    LMB G 5500-RE 1340 560÷600 369 285 520 560 DN 50 DN 65 DN 80 - 705 755 775 - 930 665
    LMB G 6500-RE 1340 560÷600 369 285 520 560 DN 50 DN 65 DN 80 - 705 755 775 - 930 665
    LMB G 8300-RE 1650 590÷630 459 335 600 665 - DN 65 DN 80 DN 100 - 815 835 865 1078 770
    LMB G 9900-RE 1650 590÷630 459 335 600 665 - DN 65 DN 80 DN 100 - 815 835 865 1078 770

     

     

    Boiler connection flange dimensions

     

    flangia

     

    Model M (mm) N (mm) O (mm) P (Ø mm)
    LMB G 5500 RE 530 225 220 20
    LMB G 6500 RE 530 225 220 20
    LMB G 8300 RE 620 308 300 20
    LMB G 9900 RE 620 308 300 20

     

     

  • Fime "Standard Line"
    • Single-stage burner.
    • Suitable for medium pressurisation boilers.
    • For methane gas or LPG operation.
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • Combustion head and air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.

    Installation and maintenance

    • Easy installation thanks to the universal perforation mobile flange.
    • Suitable for operation with ramp pressure of 20 mbar and 30 mbar.

    Accessories available upon request

    • Air intake for room-sealed combustion.
    • See the Accessories section for further details.

    Certification

    • Fime burners are certified EC.

     

    Characteristics circulator:

     

    Curva fime

     

    Model Flow (m3/h) Power (kW) Motor
    (230V ~ 50Hz)
    Network attack (Ø) Gauge valve (Ø) Min.Pres.Nat.Gas (mbar*) Min.Pres.GPL(mbar*) Max. Pres. (mbar**)
    FIME 5 S-E 2,3÷3,82 22,86÷38 100 W mon. 1/2” 1/2” 17 13 65

     

    *: Minimum pressure of the gas to get the maximum power of the burner.

    **: Maximum operating pressure of the gas valves.

     

     

    Dimensions (mm):

     

    dimensioni

     

     

     

    Accessory: kit outside air intake port

     

    immagine accessorio

     

    1. Steel hose with a maximum length of 3 meters;

    2. Metal clamps to seal the flexible;

    3. Rigid tube with a diameter of 60 mm for the crossing of the wall;

    4. Windproof terminal located outside the dwelling;

    5. 90° elbow and gasket;

    6. Cover the air intake.

     

     

    Mounting flange and Weight:

     

    flangia

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (mm) M (mm) N (mm) Weight (kg)
    FIME 5 S-E 95 140 40÷180 M8 180 155 12
  • Em-E "Domestic Line"
    • Single-stage burners (Em) and single-stage burners with long nozzle distributor (Em L).
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. Em 16-E - Em 26-E a conversion kit is necessary).
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • Combustion head control (external in mod. Em 26-E - Em 35-E).
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap (excluding mod. Em 35-E).
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge (mod. Em 26-E - Em 35-E).
    • Easy installation thanks to the universal perforation mobile flange (sliding from mod. Em 9-E to Em 35-E).

    Accessories available upon request

    • Accessory set kit.
    • Methane to LPG conversion kit (for mod. Em 16-E and Em 26-E).
    • Valve seal control kit.

    Certification

    • Em-E burners are certified EC.

     

    Characteristics circulator:

     

    Curva em-e

     

    Curva em-e 2

     

    Model Flow (m3/h) Power (kW)    Motor       (230V~50Hz) Network attack (Ø) Gauge valve (Ø) Min. Pres. Nat. gas (mbar**) Min. Pres. G.P.L. (mbar) Max. Pres (mbar)
    EM 3-E.D1 1,19÷3,79 11,9÷37,7 100 W mon. 1/2” 1/2” 12,5 10,5 65
    EM 3-E.D2 1,19÷3,79 11,9÷37,7 100 W mon. 1/2” 1/2” 12,5 - 200
    EM 3-E.D3 1,19÷3,79 11,9÷37,7 100 W mon. 3/4” 1/2” 11 - 360
    EM 6-E.D1 2,71÷6,69 27÷66,6 100 W mon. 1/2” 1/2” 24 14 65
    EM 6-E.D2 2,71÷6,69 27÷66,6 100 W mon. 1/2” 1/2” 24 - 200
    EM 6-E.D3 2,71÷6,69 27÷66,6 100 W mon. 3/4” 1/2” 16 - 360
    EM 9-E.D2 4,32÷9 43÷89,5 100 W mon. 1/2” 1/2” 33 19 200
    EM 9-E.D3 4,32÷9 43÷89,5 100 W mon. 3/4” 1/2” 18 - 360
    EM 12-E.D6 5÷12,07 49,8÷120 100 W mon. 1” 1” 12 - 360
    EM 12-E.D3 5÷12,07 49,8÷120 100 W mon. 1/2” 1/2” 22 11 360
    EM 12/L-E.D6 5÷12,07 49,8÷120 100 W mon. 1” 1” 12 - 360
    EM 12/L-E.D3 5÷12,07 49,8÷120 100 W mon. 1/2” 1/2” 22 11 360
    EM 16-E.D3 8÷16,1 80÷160 110 W mon. 3/4” 1/2” 29 28 360
    EM 16-E.D4 8÷16,1 80÷160 110 W mon. 3/4” 3/4” 18 - 360
    EM 18-E.D6 9,9÷17 99÷169 185 W mon. 1” 1” 11 - 360
    EM 18-E.D3 9,9÷17 99÷169 185 W mon. 1/2” 1/2” 27 14 360
    EM 18/L-E.D6 9,9÷17 99÷169 185 W mon. 1” 1” 11 - 360
    EM 18/L-E.D3 9,9÷17 99÷169 185 W mon. 1/2” 1/2” 27 14 360
    EM 26-E.D6 12,9÷24,6 129÷245 220 W mon. 1” 1” 20 - 360
    EM 26-E.D3 12,9÷24,6 129÷245 220 W mon. 3/4” 1/2” 53 - 360
    EM 26-E.D4 12,9÷24,6 129÷245 220 W mon. 3/4” 3/4” - 28 360
    EM 35-E.D7 18,9÷32,1 188÷320 370 W mon. 1 1/4” 1 1/4” 18 - 360
    EM 35-E.D4 18,9÷32,1 188÷320 370 W mon. 3/4” 3/4” 46 26 360

     

    Dimensions (mm):

     

    dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) D1 (mm) E (mm) F(Ø mm) N* (mm) O* (mm)
    EM 3-E 250 215 320 90 160 80 410 145
    EM 6-E 280 247 342 90 195 80 410 145
    EM 9-E 280 247 417 40÷140 195 90 445 145
    EM 12-E 230 285 483 60÷125 232 114 485 240
    EM 12/L-E 230 285 633 60÷275 232 114 485 240
    EM 16-E 310 282 480 60÷150 215 108 465 210
    EM 18-E 275 340 550 60÷150 274 114 540 240
    EM 18/L-E 275 340 675 60÷275 274 114 540 240
    EM 26-E 360 350 750 100÷265 275 140 550 240
    EM 35-E 420 423 880 120÷310 350 140 740 260

     

    The dimensions are relative to the burner ramp from 20 mbar installed.

     

    Mounting flange and Weight:

     

    flangia

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm)

    Weight (kg)

    EM 3-E 85 135÷160 M8 170 144

    11

    EM 6-E 85 135÷160 M8 170 144 12.5
    EM 9-E 95 135÷160 M8 180 154 12.5
    EM 12-E 120 155÷210 M8 180 180 11
    EM 12/L-E 120 155÷210 M8 180 180 16
    EM 16-E 115 150÷200 M8 166 166 16
    EM 18-E 120 155÷210 M8 180 180 15.5
    EM 18/L-E 120 155÷210 M8 180 180 23
    EM 26-E 155 172÷225 M10 205 205 30
    EM 35-E 155 172÷225 M10 205 205 44
  • Em ST "Domestic Line"
    • Single-stage burners with possibility of external air intake.
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation.
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • Combustion head control.
    • Burner-external combustion air control.
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation

    • Easy installation thanks to the universal perforation mobile flange.

    Accessories available upon request

    • Accessory set kit

    Certification

    • Em ST burners are certified EC.

     

    Characteristics circulator:

    Curva em-st

     

    Curva em-st 2

     

    Model Flow (m3/h) Power (kW)   Motor   (230V~50Hz) Network attack (Ø) Gauge valve  (Ø) Min. Pres. Nat. Gas (mbar) Min. Pres. G.P.L. (mbar) Pres.max. (mbar)
    EM 3 ST-E D1 1,61÷3,52 16÷35 100 W mon. 1/2” 1/2” 12,5 10,5 65
    EM 3 ST-E D2 1,61÷3,52 16÷35 100 W mon. 1/2” 1/2” 12,5 - 200
    EM 3 ST-E D3 1,61÷3,52 16÷35 100 W mon. 3/4” 1/2” 11 - 360

     

    Dimensions (mm):

     

    dimensioni

    (*): The dimensions are relative to the burner ramp from 20 mbar installed.

     

    Mounting flange and Weight:

     

    flangia

     

    Model Weight (body + gas train) (kg)
    EM 3 ST-E D1 11 + 2
    EM 3 ST-E D2 11 + 1,5
    EM 3 ST-E D3 11 + 2
  • Em/2-E "Domestic Line"
    • Two-stage burners.
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. Em16/2-E - Em 26/2-E - a conversion kit is necessary).
    • Gas ramp with stabiliser, dual valve and filter.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge (mod. Em 26/2-E - Em 40/2-E).
    • Easy installation thanks to the universal perforation mobile flange.

    Accessories available upon request

    • Accessory set kit.
    • Methane to LPG conversion kit (for mod. Em 16/2-E - Em 26/2-E).
    • Valve seal control kit.

    Certification

    • Em/2-E burners are certified EC.

     

    Characteristics circulator:

     

    Curva em-2-e

     

    Model Flow (m3/h) Power (kW) Motor  (230V~50Hz) Network attack  (Ø) Gauge valve (Ø) Min. Pres. Nat. Gas (mbar) Min. Pres. G.P.L. (mbar) Press. max. (mbar)
    EM 9/2-E.D3 4,3÷9 43÷89,5 100 W mon. 3/4” 1/2” 18 19 360
    EM 16/2-E.D3 5,5÷15,3 55÷153 150 W mon. 3/4” 1/2” 28 27 360
    EM 16/2-E.D4 5,5÷15,3 55÷153 150 W mon. 3/4” 3/4” 19 - 360
    EM 18/2-E.D6 9,9÷17 99÷169 185 W mon. 1” 1” 12 - 360
    EM 18/2-E.D3 9,9÷17 99÷169 185 W mon. 3/4” 1/2” 23 14 360
    EM 26/2-E.D6 9÷23,2 90÷231 220 W mon. 1” 1” 18 - 360
    EM 26/2-E.D3 9÷23,2 90÷231 220 W mon. 3/4” 1/2” 43 - 360
    EM 26/2-E.D4 9÷23,2 90÷231 220 W mon. 3/4” 3/4” - 31 360
    EM 40/2-E.D7 11,5÷39,2 115÷390 370 W mon. 1 1/4” 1 1/4” 23 - 360
    EM 40/2-E.D4 11,5÷39,2 115÷390 370 W mon. 3/4” 3/4” 62 32 360

     

    Dimensions (mm):

     

    Dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) E (mm) F (Ø mm) N* (mm) O* (mm)
    EM 9/2-E 280 247 417 40÷140 195 90 515 195
    EM 16/2-E 310 282 480 60÷150 215 108 535 210
    EM 18/2-E 275 340 675 60÷275 274 114 640 240
    EM 26/2-E 360 350 750 100÷265 275 140 650 240
    EM 40/2-E 420 423 880 120÷310 350 140 835 260

     

    *: The dimensions are relative to the burner ramp from 20 mbar installed.

     

     

    Mounting flange and Weight:


    Flangia

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm) Weight (kg)
    EM 9/2-E 95 140÷180 M8 180 154 14
    EM 16/2-E 115 150÷200 M8 166 166 18
    EM 18/2-E 120 155÷210 M8 180 180 25
    EM 26/2-E 155 172÷225 M10 205 205 31
    EM 40/2-E 155 172÷225 M10 205 205 44
  • Em/M-E "Domestic Line"
    • Two-stage progressive burners.
    • Possibility of continuous modulation operation with the application of the modul. kit
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation (for mod. Em 16/M-E - Em 26/M-E  - a conversion kit is necessary).
    • Gas ramp with dual pneumatic valve and built-in stabiliser.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Soundproof bonnet.
    • Compact size.
    • Can be combined with various types of gas ramps for ultimate versatility.
    • Supplied in 2 boxes (Burner + Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge (mod. Em 26/M-E).
    • Easy installation thanks to the universal perforation sliding flange.

    Accessories available upon request

    • Accessory set kit.
    • Modul.(temperature/pressure) kit for continuous modulation.
    • Methane to LPG conversion kit (for mod. Em 16/M-E - Em 26/M-E).
    • Valve seal control kit.

    Certification

    • Em/M-E burners are certified EC.

     

    Characteristics circulator:

    Curva em-m-e

     

     

    Model Flow (m3/h) Power (kW) Motor  (230V~50Hz) Network attack  (Ø) Gauge valve (Ø) Min. Pres. Nat. Gas (mbar) Min. Pres. G.P.L. (mbar) Press. max. (mbar)
    EM 16/M-E.D4 5,5÷15,3 55÷153 150 W mon. 3/4” 3/4” 17 22 360
    EM 26/M-E.D7 9÷23,2 90÷231 220 W mon. 1 1/4” 1 1/4” 15 - 360
    EM 26/M-E.D4 9÷23,2 90÷231 220 W mon. 3/4” 3/4” - 30 360
    EM 26/M-E.D5 9÷23,2 90÷231 220 W mon. 3/4” 3/4” 25 - 360
    EM 40/M-E.D7 11,5÷39,2 115÷390 370 W mon. 1 1/4” 1 1/4” 18 - 360
    EM 40/M-E.D4 11,5÷39,2 115÷390 370 W mon. 3/4” 3/4” - 25 360
    EM 40/M-E.D5 11,5÷39,2 115÷390 370 W mon. 3/4” 3/4” 45 - 360

     

    Dimensions (mm):

     

    Dimensioni

     

    Model A (mm) B (mm) C (mm) D (mm) E (mm) F (Ø mm) N* (mm) O* (mm)
    EM 16/M-E 310 282 480 60÷150 215 108 535 210
    EM 26/M-E 360 350 750 100÷265 275 140 650 240
    EM 40/M-E 420 423 880 120÷310 350 140 740 290

    Mounting flange and Weight:

     

    Flangia

     

    Model G (Ø mm) H (Ø mm) I (Ø mm) L (Ø mm) M (Ø mm) Weight (kg)
    EM 16/M-E 115 150÷200 M8 166 166 18
    EM 26/M-E 155 172÷225 M10 205 205 30
    EM 40/M-E 155 172÷225 M10 205 205 44
  • Pm/M-E "Industrial Line"
    • Two-stage progressive burners.
    • Possibility of continuous modulation operation with the application of the modul. kit
    • Suitable for pressurised boilers.
    • For methane gas or LPG operation.
    • Low emissions.
    • External combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Standard valve seal control in models 310 and 430.
    • Shock-resistant electrical panel.
    • Can be combined with various types of ramps for ultimate versatility.
    • Supplied in two boxes (Burner+Gas ramp).

    Installation and maintenance

    • Fitted with full inspection hinge.
    • Easy installation thanks to the universal perforation sliding flange.

    Accessories available upon request

    • Accessory set kit.
    • Modul.(temperature/pressure) kit for continuous modulation.

    Certification

    • Pm/M-E burners are certified EC.

     

    Characteristics circulator:

     

    campo di lavoro

     

    Model Flow (m3/h) Power
    (kW)
    Motor
    (230V~50Hz)
     Network attack
    (Ø)
     Gauge  valve  
    (Ø)
    Min.P.Nat.Gas
    (mbar)
    Min.Pr.G.P.L.
    (mbar)
    Press.max.
    (mbar)
    310 PM/M-E.F10 94÷290 940÷2.900 5.500 W tri. DN100 DN100 28 - 360
    310 PM/M-E.F8 94÷290 940÷2.900 5.500 W tri. DN65 DN65 67 - 360
    310 PM/M-E.F8 94÷290 940÷2.900 5.500 W tri. DN65 DN65 - 25 360
    430 PM/M-E.F10 110÷430 1.100÷4.275 9.200 W tri. DN100 DN100 29 - 360
    430 PM/M-E.F8 110÷430 1.100÷4.275 9.200 W tri. DN65 DN65 99 - 360
    430 PM/M-E.F8 110÷430 1.100÷4.275 9.200 W tri. DN65 DN65 - 30 360

     

    Dimensions (mm):

     

    dimensioni

     

    Model A (mm) B* (mm) C (mm) D (mm) E (Ø mm)
    310 PM/M-E 1.710 855 700 250÷550 256
    430 PM/M-E 1.760 855 700 250÷600 303

     

    *: The dimensions are relative to the burner ramp with the likes largest installed.

     

    Mounting flange and Weight:

     

    flangia

     

    Modello F (Ø mm) H (mm) L (mm) M (mm) N (mm) Weight (kg)
    310 PM/M-E 270 235 M16 320 320 173
    410 PM/M-E 320 380÷440 M16 400 400 238
  • Lmb G "Industrial Line"
    • Two-stage progressive burners with short nozzle distribution (mod. BC) and long nozzle distributor (mod. BL).
    • Possibility of continuous modulation operation with the application of the modul. kit
    • Suitable for pressurised boilers.
    • For methane gas operation.
    • Low emissions.
    • Combustion head control.
    • Electrical servo-control on the air shutter.
    • Stabilised ventilation.
    • Excellent combustion thanks to the uniform distribution of air.
    • Standard valve seal control in models 1,300 and 2,000.
    • Shock-resistant electrical panel.
    • Supplied in two boxes (Burner+Gas ramp).

    Installation and maintenance

    • Easy installation and maintenance thanks to the full inspection hinge.

    Accessories available upon request

    • Accessory set kit.
    • Modul.(temperature/pressure) kit for continuous modulation.
    • Valve seal control kit in models 300, 450, 700, 1000.

    Certification

    • Lmb G burners are certified EC.

     

     

    curve lmb g

     

    Model burner  
    NATURAL GAS

    Flow (m3/h)

    Power 
    (kW)

    Motor
    (230V~50Hz)

    Network attack (Ø)

     Gauge valve (Ø)

    Min.Pr.Nat.Gas
    (mbar)

    Press. max.(mbar)

    LMB G 300 (K 1”-125) 11,6÷33,9 110÷320 370 W mon. 1” 1” 26 500
    LMB G 300 (K 1”-225) 11,6÷33,9 110÷320 370 W mon. 1” 1 1/2” 20 500
    LMB G 300 (D 1”-300) 11,6÷33,9 110÷320 370 W mon. 1” 1” 32 360
    LMB G 450 (K 1”-125) 14,8÷48,7 140÷460 370 W mon. 1” 1” 30 500
    LMB G 450 (K 1”-225) 14,8÷48,7 140÷460 370 W mon. 1” 1 1/2” 20 500
    LMB G 450 (D 1”-700) 14,8÷48,7 140÷460 370 W mon. 1” 1 1/2” 21 360
    LMB G 700 BC - K 1” 14,0÷79,0 135÷748 740 W tri. 1” 1” 58 500
    LMB G 700 BL - K 1” 14,0÷79,0 135÷748 740 W tri. 1” 1” 58 500
    LMB G 700 BC - K 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 500
    LMB G 700 BL - K 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 500
    LMB G 700 BC - D 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 360
    LMB G 700 BL - D 1 1/2” 14,0÷79,0 135÷748 740 W tri. 1 1/2” 1 1/2” 18 360
    LMB G 1000 BC - K 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 35 500
    LMB G 1000 BL - K 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 35 500
    LMB G 1000 BC - K 2” 16,0÷103,0 152÷979 1.100 W tri. 2” 2” 20 500
    LMB G 1000 BL - K 2” 16,0÷103,0 152÷979 1.100 W tri. 2” 2” 20 500
    LMB G 1000 BC - S 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 18 600
    LMB G 1000 BL - S 1 1/2” 16,0÷103,0 152÷979 1.100 W tri. 1 1/2” 1 1/2” 18 600
    LMB G 1300 - K 1 1/2” 25,0÷136,5 237÷1.296 2.200 W tri. 1 1/2” 1 1/2” 50 500
    LMB G 1300 - K 2” 25,0÷136,5 237÷1.296 2.200 W tri. 2” 2” 22 500
    LMB G 1300 - S 2” 25,0÷136,5 237÷1.296 2.200 W tri. 2” 2” 14 600
    LMB G 1300 - S 1 1/2” 25,0÷136,5 237÷1.296 2.200 W tri. 1 1/2” 1 1/2” 19 600
    LMB G 2000 - S 1 1/2” 36,5÷202 336÷1.918 3.000 W tri. 1 1/2” 1 1/2” 40 600
    LMB G 2000 - K 2” 36,5÷202 336÷1.918 3.000 W tri. 2” 2” 45 500
    LMB G 2000 - S 2” 36,5÷202 336÷1.918 3.000 W tri. 2” 2” 30 600
    LMB G 2000 - S DN 65 36,5÷202 336÷1.918 3.000 W tri. DN 65 DN 65 18 700

     

     

    Dimensions (mm):

     

    dimensioni

     

    *: The dimensions are relative to the burner ramp with the likes largest installed.

     

    Model A* (mm) B (mm) C (mm) D (mm) E (Ø mm)
    LMB G 300 805 340 370 230 124
    LMB G 450 805 340 370 230 138
    LMB G 700 BC 950 370 540 235 166
    LMB G 700 BL 950 370 540 325 166
    LMB G 1000 BC 850 370 540 230 196
    LMB G 1000 BL 850 370 540 350 196
    LMB G 1300 1.070 440 620 340 232
    LMB G 2000 1.070 440 620 340 244

    Mounting flange and Weight:

     

    flangia

     

    Model G (Ø mm) H (Ø mm) L (mm) M (mm) N (mm) Weight (kg)
    LMB G 300 135 194÷234 M12 216 216 18
    LMB G 450 150 194÷234 M12 216 216 18
    LMB G 700 BC 180 246÷286 M12 268 268 30
    LMB G 700 BL 180 246÷286 M12 268 268 30
    LMB G 1000 BC 205 246÷286 M12 268 268 31
    LMB G 1000 BL 205 246÷286 M12 268 268 31
    LMB G 1300 255 294÷334 M12 316 316 45
    LMB G 2000 255 294÷334 M12 316 316 48
  • Em LN "Low NOx" domestic line
    • Single-stage burners.
    • Ultra low NOx emissions (class 3  80 mg/kWh achieved thanks to a special combustion head.
    • Suitable for pressurised boilers.
    • For methane gas operation.
    • Gas ramp with stabiliser, dual valve and filter.
    • Adjustable combustion head.
    • Burner-external combustion air controller (mod. Em 4 LN - Em 7 LN) or burner-internal combustion air controller (mod. EM 13 LN).
    • Air shutter with gravity stop flap.
    • Stabilised ventilation.
    • Uniform distribution of air for optimum combustion.
    • Low sound pressure.
    • Compact size.
    • On request: possibility of other versions or other gas ramp combinations.

    Installation and maintenance

    • Easy installation thanks to the universal perforation mobile flange (sliding in mod. Em 13 LN).

    Accessories available upon request

    • Accessory set kit.
    • Valve seal control kit.

    Certification

    • Em LN burners are certified EC.

© Copyright Lamborghini Calor 2014. All Rights Reserved.
Lamborghini Calor S.p.A. - Via Statale, 342 - C.P. 46 - 44047 Dosso - FE - Italy - UNI EN ISO 9001 Certified Company
Capitale Sociale € 827.112,00 int. vers. - Cod. Fisc. - P.Iva e Reg. Impr. Ferrara n° 00173420381 Sole Shareholder Management and coordination of Ferroli S.p.A.